3. OPERATION

The set value of the floor temperature is adjusted by rotating adjusting wheel with a screwdriver (Fig.
3). The heating is switched on when the temperature measured by the sensor is lower than the set
value of the thermostat.
The fixed temperature reduction (-5°C) of the thermostat affects the temperature setting of the floor
directly.
The correspondence between the set value and the temperature of the floor is described in Table 1.
Table 1
Set value
Floor temperature (ºC)
0
1
2
3
4
5

4. TECHNICAL DATA

Supply voltage:
Adjustment range:
Load (max):
Operating temperature range: -30...+30 °C'
Temperature reduction:
Floor-sensor:
Circuit fuse:
Protection class:
1. SISSEJUHATUS
EST
ECO16FD on põrandatermostaat paigaldusega DIN-liistule.
Seadmel ei ole lülitit, kuid see tuleb kindlasti ahelasse eraldi paigaldada. Põrandaküte peab olema ühen-
datud läbi rikkevoolukaitse.
2. PAIGALDAMINE
Kinnita põrandatermostaat Din-liistule nii nagu on näidatud Joonisel 1. Vaata ühendusskeemi Joo-
nisel 2.
Ühenda temperatuurialandus termostaadi klemmile 'T-' . Temperatuurialandus hakkab tööle välise
pinge lülitamisel ükskõik millisest faasist antud klemmile.
Kontrolli, et juhitav küttevõimsus ei ületa termostaadile lubatavat nimikoormust. Kontrolli termos-
taadi poolt juhitava kütteahela takistust ja küttekaabli isolatsioonitakistust.
Paigalda anduri kaabel kaitsetorusse kahe kaabliahela vahele. MÄRKUS! Veendu, et kaitsetorus po-
leks vett.
NB! Lülita toitepinge välja enne paigaldust või hooldust. Käesolev paigaldusjuhend tuleb alles hoida või-
malikke hooldustöid silmas pidades.
6
5
14
22
30
40
50
230 V /50 Hz, -15% / +10%
5 - 50 °C
3600W, 16A cosϕ = 1 / 2A cosϕ = 0,4
fixed –5 °C, control 230V
NTC, 47 kΩ at 25°C, cable 4 m (extendable up to 25 m)
16A
IP20