4.4. Check that the power button in the cover is on down position and also the switch pin on the thermo-
stat is on down position (1).
4.5. Install the frame and carefully press the cover with display onto the thermostat. Place the upper part
(2) first and then press the lower part (3) to its place.
4.6. Confirm the placement by carefully pushing the cover onto the thermostat (4).
4.7. Start the thermostat by switching the power button on the thermostat to up position (5).
Warning! Do not apply pressure to the corners of the display cover or to the display itself.
1
5.
UNINSTALLATION
5.1. Make sure the power switch is in down position, power off (6).
5.2. Press the cover latch carefully with screwdriver to open the cover plate from bottom (7) and remove
the cover (8). Warning! Do not open the four latches on the backside of the thermostat (9).
5.3. Uninstall the frame.
5.4. Open the 2 screws from the mounting box.
6
6.

OPERATION

6.1. The thermostat starts when ON/OFF switch is in up position. In down position the thermostat is off.
6.2. First connection will start an installer Wizard which will setup the device.
NOTE! The thermostat is equipped with a sensitive touch screen. Tap the touch screen with fingertips lightly.
2
3
8
7
Region: Select time region
Language: Select language which the thermostat will use
Date: Set the current date dd.mm.yyyy
Time: Set the current time hh:mm
Floor type: Select "Tile floor" or "Wooden floor"
Confirm the settings with
4
4
9
or discard with
5
N
L
L
N
Sensor
ECO16TOUCH
IP 21 T25
16A / 230 VAC, 50Hz
Under oor heating thermostat