Download Print this page

Sharp SL-5500 Service Manual page 59

Personal mobile tool
Hide thumbs Also See for SL-5500:

Advertisement

PC-UM10M
5) SERIAL PORT TEST (SOME OF SHARP I/O PORTS (16PIN CONNECTORS))
1. Control line test
Test by Diag
Test jig: Use the following circuit. (Prepare it on each service spot.)
1
Open "DIAG MENU (2/3) ".
2
Connect the following test circuit.
3
Tap "No1 16pin."
Display
=== 16pin Test ===
16pin test Complete
Hit any key to continue
----Status messages----
OK
Test circuit
14 pin
DTR
7 pin
DSR
5 pin
RTS
6 pin
CTS
10 pin WAKEUP
Note: Supply this IC power from
VCC-GND of 16in connector.
ic:74HC14 or 74HC04
2. Data line test
Test by Diag
Test jig:CE-170TS
PC (with RS-232 (9pin) support)
1
2
3
Push and hold "R" and "D", and push Full Reset at the same
time.
4
5
SL5500 displays as follows:
Alarm Check
Wait 1s
OK
6
7
Execute Full Reset.
Remove the CE170TS.
Note: When "R" + "D" keys and Full Reset are pushed at the same time, the machine enters the test mode.
Be careful no to touch the keys of PC at that time.
1 Check that "OK" is indicated.
Test content
1
Make RTS="H".
Make DTR="L".
2
Make RTS="L".
Make DTR="L".
3
Make RTS="L".
Make DTR="H".
4
Make RTS="H".
Make DTR="H".
SL5500
SL-5500 DIAGNOSTICS AND CHECK ITEMS
Check that CTS="L"
Check that WAKEUP="H"
Check that DSR="H"
Check that CTS="H"
Check that WAKEUP="L"
Check that DSR="H"
Check that CTS="H"
Check that WAKEUP="L"
Check that DSR="L"
Check that CTS="L"
Check that WAKEUP="H"
Check that DSR="L"
The terminal adapter confirmed by Technical Division is Tera Term (Pro)
(Free software of terminal emulator (communication program) .)
Connect the CE-170TS, and boot the terminal adapter.
Terminal adapter setup
Speed
Parity
Data length
Stop bit
Xon/Xoff
Shift in/out
The PC's display indicates "READY REMOTE CHECK."
Enter "RA" in caps.
If entered in small letters, "raNG Command error" is displayed.
The screen displays as:
RAOK
– 58 –
Check content
PC
2400 (bps)
None
8bit
1bit
Not used
Not used

Advertisement

loading