Download Print this page

Sharp SL-5500 Service Manual page 55

Personal mobile tool
Hide thumbs Also See for SL-5500:

Advertisement

PC-UM10M
DISPLAY DENSITY ADJUSTMENT, WRITING
DIAG MENU (1/3)
Page down
1. COM ADJ setting
Boot Flag
:
AIN1(B/U)
:
AIN1(Main)
:
AIN0
:
Tablet
:
COM
:
(Environmental conditions for display density adjustment, setting)
Kind of power source: Inverter fluorescent lamp (3-wavelength daytime white)
Panel surface illumination: 2500 m 500 lx
Ambient illumination: 300 ~ 700 lx
No.
Operating procedure
1
Connect the AC adapter to supply power to the SL-5500. Press FULL RESET button to boot
the DIAG mode. If the DIAG is not booted by pressing FULL RESET button, press and hold
[P] + [D] and press FULL RESET button simultaneously.
2
Press Front Light key to turn on the light.
4
Press [OK] key.
5
Check for the set value which provides no flicker
of display with the cursor key.
6
Remember the adjustment value of the display,
and press [UPDATE] of tablet.
7
Press Front Light key to turn off the light.
8
Press [on/off] key to turn off the power. After the display is turned off completely, disconnect
the AC adapter.
Page up
- - -
V
:
CF CD
:H
SD CD
:H
SD WP
:H
M.B.L
:
Version
DIAG MENU (1/3)
Adjustment value
DIAG MENU (1/3)
DIAG MENU (1/3)
SL-5500 DIAGNOSTICS AND CHECK ITEMS
Display
+100
+10
+1
CLA
-100
-10
-10
UPDATE
Set value
+10
-1
+1
-10
– 54 –
Check item
Front Light turns on.
There is no flicker of display.
COM: ***** becomes the set value.
F/L turns off.

Advertisement