Reference Manual
00809-0100-4021, Rev AA
March 2002
Table B-2. Input Entity
Parameters
K1 Combination of E1, N1, and I1
CENELEC and CSA Approvals
KA Combination of K1 and K6
Japanese Industrial Standard (JIS) Flameproof Certification
E4 Without optional meter: Ex d IIB T6 (T
With optional meter: Ex d IIB T4 (T
Centro de Pesquisas de Energia Eletrica (CEPEL) Approval
I2
Intrinsic Safety
BR-Ex ia IIC T6 (T
Power/Loop
V
= 30 V dc
max
I
= 130 mA
max
P
= 1.0 W
max
C
= 5 nF
i
L
= 0.02 mH
i
Special Conditions for Safe Use (x):
The transmitter can only be mounted in an area where it is protected against
mechanical impacts. Only the sensor (T/C or RTD) can be mounted in Zone 0.
Standard Australia Quality Assurance Services (SAA)
E7 Flameproof Approval
Ex d IIC T6 (T
= –20 to 60 °C)
amb
N7 Type N Approval
Ex n IIC T6 (T
= –40 to 50 °C)
amb
Ex n IIC T5 (T
= –40 to 75 °C)
amb
I7
Intrinsic Safety Approval
Ex ia IIC T5 (T
amb
amb
= 60 °C)
amb
= 60 °C)
amb
Sensor
V
= 10.7 V dc
t
I
= 15.3 mA
t
P
= 40 mW
max
C
= 2.23 µF
a
L
= 140 mH
a
= –40 to 75 °C)
Model 3144P