These next pages can help troubleshoot problems that might occur after installation is complete.
obd port black box
Download a simple .txt file to troubleshoot gate operator errors and view event history.
1. Plug MAX USB flash drive into OBD port. OBD LED will flash while file is downloading.
Remove flash drive after LED stops flashing (up to 5 minutes to download).
2. Plug flash drive into any computer USB port OR smart phone using a USB phone adapter.
The most recent 8000 events can be viewed. No special software required.
BATTERY
DSP ARM CONTROLLER
BATTERY VOLTAGE
INPUT
ERROR
E
1/2
F
BATTERY
BATTERY
INPUT
BACKUP MODE
BATTERY
LEAVE
OPEN
IN USE
OPEN
1 TIME
REPLACE
LEAVE
BATTERY
BATTERY
CLOSED
TEST
POWER /
SOLAR IN
POWER
ERD SENSITIVITY
14
12
14
12
16
16
MIN
MIN
ERD
ERD
1
9
1
9
MAX
MOTOR
MAX
MOTOR
MODULE
SENSE
OVER
SENSE
OVER
PORT
3
7
3
7
LOAD
LOAD
OPENING
CLOSING
OBD PORT
BLACK BOX
MAXIMUM CONTROLS
RESET
OFF
DSP ARM CONTROLLER
1
2
ALARM
3
4
5
PROGRAMMING
MOTION CONTROL
ID PLUG
6
ERROR
1
2
ID
3
4
PLUG
5
6
7
OPEN
STOP
CLOSE
PROGRAM
8
9
10
OFF
ANTI-
PUSH
PULL
EXIT PWR
TAILGATE
SOLAR MODE
OPEN
OPEN
EXIT
LOOP
OFF
ON
GND
OFF
ON
GATE
CENTER
LOOP
LOOP PWR
CLOSING GATE SPEED
SAFETY
LOOP
OPERATOR
MIN
MIN
FAULTS
MAX
MAX
SINGLE
DUAL
24VDC OUTPUT
GND
MOTOR 1
MOTOR 2
12VDC OUTPUT
GND
test photo cls nc sensor
Troubleshoot
PHOTO CLS NC
1. Press and HOLD the STOP button & then the OPEN button together until beeping is heard, learn mode begins.
NOTE: DO NOT press the OPEN button before the STOP button or learn mode will NOT function.
2. PHOTO CLS NC LED should be ON if an entrapment sensor is detected.
If PHOTO CLS NC LED is NOT on, sensor has a problem.
Possible problems:
•
Photocells are out of alignment
•
Photocells are wired wrong - N.C. or N.O. depending on which
type of photocells are used
•
Sensor is bad
3. Press STOP button again within 5 min. to end learn mode, beeping stops.
NOTE: If STOP button is not pressed within 5 min. learn mode automatically end after 5 min.
MAX Super 1300/2300 Arms V1
troubleshooting
MOTOR 1
[+]
INPUTS
[-]
[+]
MOTOR 2
INPUTS
[-]
LIMIT 1
MOTOR 1
LIMIT 2
LIMIT 1
MOTOR 2
CLOSE
LIMIT 2
U S
TIMER
A d
LIMIT 1
R e
MIN
MAX
MOTOR 1
GND
OFF
LIMITS
LIMIT 2
LIMIT 1
MOTOR 2
GND
LIMITS
ON/OFF
LIMIT 2
BATTERY
JOG
GATE OPEN
COM
GATE CLOSED
GND
OPEN
CLOSE
MAG
NO
LOCK
COM
NC
MAGLOCK
DELAY
OPEN ONLY NC
M A
PHOTO CLS NC
OFF
2.5 sec
OPEN / CLS NC
F l a
1.5 sec
12VDC OUT
X
GND
s h
OPEN ONLY 10K
UL
ENTRAP
CLS ONLY 10K
D r i
OPEN / CLS 10K
12VDC OUT
GND
entrapment protection sensor (Photocell typically used):
S m
a r t
P h o
n e
n e
h o
C o m
B P
p u t
e r
a p t
e r
d
i r e
q u
O R
v e
OPEN ONLY
P
P
P
P
PHOTO CLS
OPEN/CLS
12VDC OUT
OPEN ONLY
CLS ONLY
OPEN/CLS
12VDC OUT
Event History Text Document Sample
Event type clarifica�on:
INFO: informa�onal message only
WARNING: unusual event but doesn't cause system malfunc�on
ERROR: abnormal event, could cause system malfunc�on
ENTRAP: entrapment detec�on event
Event Report:
Fri 07/11/2021 10:59:41
INFO : Cycle Counter
Fri 07/11/2021 10:59:41
ENTRAP : SEC_MC: First ERD Detected
Fri 07/11/2021 10:59:37
INFO : Radio Input Deac�vated
Fri 07/11/2021 10:59:36
INFO : Radio Input Ac�vated
Fri 07/11/2021 10:58:54
INFO : PRI_MC: Fully Open Posi�on Learned
Fri 07/11/2021 10:58:53
INFO : SEC_MC: Fully Open Posi�on Learned
Fri 07/11/2021 10:57:40
INFO : PRI_CIO: Communica�on Established
Fri 07/11/2021 10:57:38
ENTRAP : PRI_MC: Photo Cell Deac�vated
Fri 07/11/2021 10:57:34
ENTRAP : PRI_MC: Photo Cell Ac�vated
Fri 07/11/2021 10:57:21
INFO : Radio Input Deac�vated
Fri 07/11/2021 10:57:21
INFO : Radio Input Ac�vated
Fri 07/11/2021 10:56:46
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2021 10:56:36
INFO : SEC_MC: Fully Open Posi�on Unknown
Fri 07/11/2021 10:56:36
INFO : PRI_MC: Fully Open Posi�on Unknown
Fri 07/11/2021 10:56:36
WARNING: PRI_MC: Tamper Reported
Fri 07/11/2021 10:56:33
ENTRAP : PRI_MC: Photo Cell Deac�vated
Fri 07/11/2021 10:56:33
ENTRAP : PRI_MC: Photo Cell Ac�vated
Fri 07/11/2021 10:56:33
ENTRAP : PRI_MC: Photo Cell Deac�vated
Fri 07/11/2021 10:56:33
ENTRAP : PRI_MC: Photo Cell Ac�vated
OPEN STOP
NC
NC
NC
NC
Power
GND
10K
Closing Direction
10K
10K
automatically monitored
GND
MOTION CONTROL
STOP
OPEN
CLOSE
MOTION CONTROL
CLOSE
39
Need help?
Do you have a question about the MAX SUPER ARM 1300 and is the answer not in the manual?