Installation - Gas Connection - Daniela DAN2GTS User Manual

2,4 & 5 burner
Table of Contents

Advertisement

Rangehoods and overhead exhaust fans must be installed according to the manufacturer's
instructions and AS5601, but in no case shall clearance from hob burners be less than 600mm for
the rangehood and 750mm for the overhead exhaust fan. It is recommended that the adjacent
kitchen surfaces should be capable of withstanding temperatures of 100ºC.
Refer also AS5601 for installation requirements.
MODEL
64GTS
75GTS
95GTS
The hotplate must be secured to the bench using the supplied brackets and attached to ensure
hotplate does not move (in position).

INSTALLATION - GAS CONNECTION

These Technical Instructions have been prepared for use by Authorised persons. This unit
must only be installed by an Authorised person e.g. licensed plumber and gasfitter.
This appliance is for use with connections using rigid copper connection or;
this appliance is suitable for installation with a flexible hose connection. Hose connection
must be to AS1869 – Class B and be no more than 1.5 metres in length. Hose must be
support independent of any surface which may become hot.
Gas Inlet fitting is ½" BSP (male) thread.
Fit the appliance inlet elbow and sealing washer and tighten, attach the regulator supplied
for Natural Gas (if applicable) as close as possible to inlet of the hotplate. For LPG
appliances, the test point adaptor (supplied) must be fitted. The supply connection is to be
accessible with the appliance installed.
It is recommended that an isolating valve and union be fitted, to enable disconnection for
servicing. These are to be in an accessible location.
Check connections are gas tight with soapy water or other approved method.
UNDER NO CIRCUMSTANCES USE A NAKED FLAME WHEN CHECKING FOR LEAKS.
Check Gas Adjustments (refer INSTALLATION – GAS CHECKS AND ADJUSTMENTS)
Ensure the appliance operating pressure is adjusted and set according to these instructions
and local authority requirements. When satisfied that the hotplate is operating correctly,
instruct the customer in its safe operation. Ensure the customer understands fully by having
them operate the hotplate and all its functions.
P
I
02 9604 1226
E
I
WIDTH
555mm
555mm
830mm
sales@danielaappliances.com.au
DEPTH
475mm
475mm
475mm
W
|
danielaappliances.com.au
PA G E 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dan64gts/1Dan64gts/2Dan7Dan75gtsDan95gtsDan95gts/1

Table of Contents