Installation - General - Daniela DAN2GTS User Manual

2,4 & 5 burner
Table of Contents

Advertisement

The installation must be carried out by a suitably qualified and authorised person,
in accordance with the current version of the following:
1.
The requirements of the local Gas and Electrical authorities must be adhered to:-
- Consult AS5601 (AG601) as appropriate
- Consult SAA Wiring rules for electrical installations as appropriate.
2.
Location of gas inlet
• 64GTS located 125mm from left side at rear
• 75GTS located 175mm from roght side at rear
• 95GTS located left side, 250mm from front 30mm in from edge.
3.
Electrical connection
• 240mm C/L from RH side (as viewed from front)
• 40mm C/L from rear
• Connection is by means of flexible cord and plug.
4.
Overall dimensions of hotplate
MODEL
64GTS
75GTS
95GTS
5.
Daniela Appliances and their appointed agents decline any responsibilities in the case of
installation is not according to these instructions.
6.
Remove any packaging, plastic film etc from appliance.
7.
Before placing hotplate in position fit the foam sealing strip on the underside, around the
perimeter. This will prevent spillage entering the cupboard under the hotplate.
IMPORTANT: WHEN THE HOTPLATE IS INSTALLED ABUTTING A SIDE OR REAR WALL,
THE WALL MUST BE OF NON-COMBUSTABLE MATERIAL, e.g. CERAMIC TILES.
The following minimum clearances to combustible materials must be observed:
Minimum clearance from hotplate edge (burner) to side wall must be 200mm.
Minimum clearance from the hotplate (burner) edge to rear wall must be 200mm.
Minimum clearance from the hotplate to cupboard above the hob burners must be
minimum of 600mm.
PA G E 8
P

INSTALLATION - GENERAL

WIDTH
580mm
680mm
860mm
I
02 9604 1226
E
I
sales@danielaappliances.com.au
DEPTH
500mm
500mm
500mm
W
|
danielaappliances.com.au
HEIGHT
80mm
80mm
80mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dan64gts/1Dan64gts/2Dan7Dan75gtsDan95gtsDan95gts/1

Table of Contents