Genie S-80HF Maintenance Manual page 114

Table of Contents

Advertisement

Maintenance Manual
Quarterly Maintenance Procedures
Note: Perform this procedure on a firm, level
surface with the machine in the stowed position.
1
Place the machine on a firm surface that has a
side slope greater than 2° (6.5 inches / 16.5
cm) but less than 5° (16 inches / 40.6 cm).
2
Place a digital level that has been calibrated to
gravity on the X axis of the turntable.
positive degree side slope
negative degree side slope
100
3
Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
4
Press the Maintenance button and select Real
Time Data. Navigate to the Turntable Tilt Roll
Data.
Result: The reading at the display and digital
level is within ± 1° of each other.
Result: The reading at the display and digital
level is greater than ± 1° of each other. The
level sensor must be calibrated. Refer to
Repair Procedure in the appropriate Service
and Repair Manual for your machine, How to
Calibrate the Turntable Level Sensor.
5
Place the machine on a firm surface that has
an uphill or downhill slope greater than 2° (6.5
inches / 16.5 cm) but less than 5° (16 inches /
40.6 cm).
6
Navigate to the Turntable Tilt Pitch screen.
S
®
Booms • Z
®
Booms
October 2018
Tip-over hazard. If the X axis is
not within ± 1°, failure to properly
calibrate the level sensor could
cause the machine to tip over
resulting in death or serious
injury. Refer to Repair Procedure
in the appropriate Service and
Repair Manual for your machine,
How to Calibrate the Turntable
Level Sensor.
Part No. 1268489GT