6.1.11 Rohs; Other Approvals; Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM RSG910C Installation Manual

Hide thumbs Also See for SIMATIC NET RUGGEDCOM RSG910C:
Table of Contents

Advertisement

Certification
6.1.11 RoHS
6.1.11
RoHS
This device is declared by Siemens Canada Ltd. to meet the requirements of the
following RoHS (Restriction of Hazardous Substances) directives for the restricted use
of certain hazardous substances in electrical and electronic equipment:
A copy of the Material Declaration is available online at
support.industry.siemens.com/cs/ww/en/view/109738831.
6.1.12

Other Approvals

This device meets the requirements of the following additional standards:
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RSG910C has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
61000-4-2
61000-4-3
61000-4-4
36
China RoHS 2
Administrative Measure on the Control of Pollution Caused by Electronic
Information Products
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
EN 50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
EN 50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
EN 50155
Railway applications – Rolling stock – Electronic equipment
Test
IEC
ESD
IEC
Radiated RFI
IEC
Burst (Fast Transient)
Description
Enclosure
Contact
Enclosure Air
Enclosure
Ports
Signal Ports
DC Power
Ports
https://
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz, 5 kHz
± 4 kV @ 2.5 kHz, 5 kHz
Installation Manual, 04/2022, C79000-G8976-1405-11
Severity
Levels
4
4
4
4
RUGGEDCOM RSG910C