IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-14
IEC 60068-2-78
IEC 60255-21-1
IEC 60255-21-2
IEC 60255-21-2
IEC 60255-21-3
RUGGEDCOM RSG910C
Installation Manual, 04/2022, C79000-G8976-1405-11
Test
Dry Heat
Dry Heat Storage
Humidity (Damp
Heat, Cyclic)
Change of
Temperature
Humidity (Damp
Heat, Cyclic)
IEC 60529
6.2 EMC and Environmental Type Tests
Description
Test Bd
Test Bd
Test Dd
Test Nb
Test Cab
Vibration
Shock
Bump
Seismic
Ingress Protection
Certification
Test Levels
Severity Levels
85 °C (185
°F), 16 Hours
85 °C (185
°F), 16 Hours
95% (Non-
Condensing),
55 °C (131
°F), 6 Cycles
5 Cycles @
-40 to 85 °C
(-40 to 185 °F)
10 Days @ 55 °C
(131 °F), 6 Cycles
2 g @ 10 to 150 Hz
30 g @ 11 ms
10 g @ 16 ms
Method A
IP4x
 
 
 
 
 
Class 2
Class 2
Class 1
Class 2
 
39