PROBLEM 4.
THE SUCTIONING SYSTEM WORKS PROPERLY BUT THE
EXTRACTABLE UNIT DOES NOT OPEN
POSSIBLE SOLUTION
CHECK IF THE ELECTRICAL SYSTEM CONNECTORS ARE CONNECTED
PROPERLY
Disconnect the downdraft from power supply
Check if the 9-pin connector male and female contacts are connected properly.
Release the movable connector wires by removing the black sheath.
Check if the connector inner contacts are inserted properly, with the help of a
screwdriver. Carry out this check in both the movable and the fixed connectors.
Check connections according to the wiring diagram are inserted properly.