Download Print this page
Caple DD903BK Instruction Manual

Caple DD903BK Instruction Manual

Downdraft hood
Hide thumbs Also See for DD903BK:

Advertisement

Quick Links

Instruction manual for downdraft hood
Model codes: DD903BK & DD522BK
Contact Caple on 0117 938 7420 or for spare parts www.caple.co.uk
www.caple.co.uk

Advertisement

loading
Need help?

Need help?

Do you have a question about the DD903BK and is the answer not in the manual?

Questions and answers

Summary of Contents for Caple DD903BK

  • Page 1 Instruction manual for downdraft hood Model codes: DD903BK & DD522BK Contact Caple on 0117 938 7420 or for spare parts www.caple.co.uk www.caple.co.uk...
  • Page 2 (the flames extracted into the downdraft might damage the appliance). ● Frying next to the appliance must be done The DD903BK & DD522BK are designed so under constant supervision as hot oils and fats they can be either externally ventilated or re may ignite.
  • Page 3: Table Of Contents

    CONTENTS DESCRIPTION OF THE APPLIANCE ..................4 INSTALLING THE DOWNDRAFT...................5 Grease filter removal, mounting the activated charcoal filter ..........6 Electrical connection of the hood ..................6 HOW THE DOWNDRAFT WORKS ..................8 CLEANING THE DOWNDRAFT.....................9 TROUBLESHOOTING......................10 AFTER SALES SERVICE ......................10...
  • Page 4: Description Of The Appliance

    DESCRIPTION OF THE APPLIANCE DD903BK LOWER AIR OUTLET BACK AIR OUTLET DD522BK...
  • Page 5: Installing The Downdraft

    DD903BK: If you intend to use the rear air exit, caused by failure to comply with the above you will first have to remove the flange from...
  • Page 6: Grease Filter Removal, Mounting The Activated Charcoal Filter

    1 x CAP72CF charcoal filter is required for the DD522BK. NOTE these can be purchased directly from www.caple.co.uk or by calling our sales office on We recommend installing the metal box 0117 938 1900 containing the electronic components at least 10 cm above floor level and at a Clean air is then recycled back into the room via a suitable distance from all heat sources (e.g.
  • Page 7 WARNING The downdraft connection to the electrica nework must be carried out only by professional and qualified technicians. The downdraft must be connected to a properly installed and suitable electrical network. The electrical system must comply with VDE0100 standard. DANGER If the downdraft presents any anomaly, disconnect the appliance or remove the fuse corresponding...
  • Page 8: How The Downdraft Works

    HOW THE TIMING As a result of the new EU65 “Energy label” and DOWNDRAFT WORKS EU66 “ Ecodesign” regulations issued by the Euro- pean Commission, which came into force as from January 1st, 2015 , our products have been adap- ted to comply with these new requirements.
  • Page 9: Cleaning The Downdraft

    CLEANING THE DOWNDRAFT Careful maintenance ensures proper operation and good performances over time. CAUTION The hood must be disconnected from the electrical network, both by unplugging the appliance from the socket and activating the magnetic circuit breaker (safety cut-out), before removing the metal grease filters.
  • Page 10: Troubleshooting

    Any maintenance operation on your appliance should be carried out by: ● Either your retailer; ● Or another Caple approved engineer or similiar qualified person. If a problem still persists and further assistance is required, please contact our Caple after sales team on: T - 0117 938 7420...
  • Page 11 Fig. 1 Fig. 2 Fig. 4 Fig. 3 Fig. 5...
  • Page 12 Fig. 7 Fig. 6 Fig. 9 Fig. 8...
  • Page 13 Fig. 10 SEZIONE A-A DD522BK with DDMEXT21 or DDMEXT30 DDMEXT21 DDMEXT30 220X90 220X90 Fig. 11...
  • Page 14 SEZIONE A-A SCALA 1 : 8 The components shown in the drawing are supplied with the SEM10 or SEM12 Fig. 13...
  • Page 16 Caple Service Fourth Way Avonmouth Bristol BS11 8DW t: 0117 938 7420 e: service@caple.co.uk www.caple.co.uk Please keep this instruction manual for future reference...

This manual is also suitable for: