Caple DD910WH Technical Information page 11

Downdraft downdraft extractor extractor
Hide thumbs Also See for DD910WH:

Advertisement

SUITABLE SOLUTIONS:
3 CHECK IF THE GREASE - FILTER SENSOR WORKS PROPERLY
3.1 Disconnect the 9-pole connector
3.2 By using a millimetre, insert the push rod into contacts no.3 (Red) and in no.6 (black)
3.3 In the presence of continuity, the sensor works properly, if there is no continuity, check if:
The panel is unhooked (Chapter 4)
The magnet in the panel is placed properly (Chapter 5)
Replace the grease-filter sensor (Chapter 6)
Replace the main board (Chapter 7)
Replace the power supply board (Chapter 8)