Download Print this page

Caple DD910WH Technical Information page 6

Downdraft downdraft extractor extractor
Hide thumbs Also See for DD910WH:

Advertisement

PROBLEMA RISCONTRATO
ITHE EXTRACTABLE DOWNDRAFT UNIT DOES NOT
OPEN AND THE SUCTIONING SYSTEM DOES NOT
WORK
THE EXCTRACTABLE UNIT WORKS, BUT THE SUC-
TIONING SYSTEM FUNCTIONS ONLY AT CERTAIN
SPEEDS
THE BODY LINER IS SCRATCHED OR DAMAGED.
THE EXTRACTABLE UNIT IS DAMAGED
THE EXTRCATBLE UNIT OPENS, BUT THE SUCTIO-
NING SYSTEM DOES NOT FUNCTION AT ANY SPEED
THE EXTRACTABLE UNIT OPENS, BUT IT DOES NOT
STOP WHEN REQUIRED, AFTER 180 mm, AND THE
SUCTIONING SYSTEM WORKS WHEN THE EXTRAC-
TABLE UNIT IS COMPLETELY OPEN, AND STOPS
WHEN THE EXTRACTABLE UNIT IS COMPLETELY
CLOSED.
SOLUZIONI
- CHECK IF NETWORK TENSION IS WORKING
- CHECK IF THE RED POWER BUTTON IS PUSHED
DOWN (chapt.1)
- CHECK IF THE ELECTRICAL SYSTEM CONNECTORS
ARE PROPERLY CONNECTED (chapt.2)
- CHECK IF THE GREASE-FILTER SENSOR IS WOR-
KING PROPERLY. (chapt.3)
- CHECK IF THE PANEL IS UNHOOKED (chapt.4)
- CHECK IF THE MAGNET ON THE PANEL IS PLACED
CORRECTLY (chapt.5)
- REPLACE THE GREASE-FILTER SENSOR (chapt.6)
- REPLACE THE MAIN ELECTRICAL SYSTEM BOARD
(chapt.7)
- REPLACE THE ELECTRICAL SYSTEM BOARD FOR
POWER DISTRIBUTION (chapt.8)
- CHECK THE CONNECTION INSIDE THE ACTUATOR
(chapt.9)
- REPLACE THE LINEAR ACTUATOR (chapt.10)
- CHECK IF THE 6-POLE MOTOR CONNECTOR IS
CONNECTED PROPERLY (chapt.11)
- CHECK IF THE SUCTIONING UNIT 6-POLE CONNEC-
TOR WIRES, IN THE MOTOR BOARD, ARE PROPERLY
CONNECTED (chapt.11)
- REPLACE THE MAIN SYSTEM ELECTRICAL BOARD
(chapt.7)
- REPLACE THE SUCTIONING UNIT IF THE DOW-
NDRAFT HAS THE MOTOR ON THE INSIDE (chapt.12)
- REPLACE THE (SEM) POWER PACK IF THE
DOWNDRAFT HAS A REMOTE MOTOR
- REPLACE THE BODY LINER (chapt.13)
REPLACE THE EXTRACTABLE UNIT (chapt.14)
- CHECK IF THE 6-POLE MOTOR CONNECTOR IS
PROPERLY CONNECTED (chapt.11)
- REPLACE THE MAIN SYSTEM ELECTRICAL BOARD
(chapt.7)
- REPLACE THE SUCTIONING UNIT, IF THE DOW-
NDRAFT HAS THE MOTOR ON THE INSIDE (chapt.12)
- REPLACE THE (SEM) POWER PACK IF THE DOW-
NDRAFT HAS A REMOTE MOTOR
- CHECK IF THE ELECTRICAL SYSTEM CONNECTORS
ARE PROPERLY CONNECTED (chapt.2)
- CHECK IF IN THE 9-POLE CONNECTOR, THE INNER
CONTACTS OF THE SENSOR CONTROLLING THE 180
mm DISTANCE ARE PROPERLY CONNECTED
(chapt.2)
- CHECK IF THE 180 mm SENSOR IS WORKING
(chapt.15)
- REPLACE THE 180mm SENSOR (chapt.16)

Advertisement

loading