JLG 1250AJP Operation And Safety Manual page 152

Hide thumbs Also See for 1250AJP:
Table of Contents

Advertisement

C: Wheel Drive Hub - Reggiana Riduttori (S/N 134389 to Pres-
ent)
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of
operation
Comments - Place Fill port at 12 o'clock position and Check
port at 3 o'clock position. Pour lubricant into fill port until it
just starts to flow out of check port.
3121170
SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
5. Hydraulic Return Filter
(See Figure 7-8., Hydraulic Return Filter Condition Indicator - Prior to S/N
139396 and Figure 7-9., Hydraulic Return Filter Condition Indicator - S/N
139396 to Present)
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours
thereafter or as indicated by condition indicator.
7-21