SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
4. A. Wheel Drive Hub (Prior to S/N 100128)
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 liters (1/2 full)
Lube - EPGL
Interval - Change after first 150 hours then every 1200
hours of operation
Comments - Place Fill port at 12 o'clock position and Check
port at 3 o'clock position. Pour lubricant into fill port until it
just starts to flow out of check port.
NOTE: After S/N 0300134389 machines may be built with either Bonfigli-
oli or Reggiana Riduttori wheel drive hubs.
7-20
B: Wheel Drive Hub - Bonfiglioli (S/N 100128 to Present)
Lube Point(s) - Level/Fill Plug
Capacity - 2.1 quarts (2 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every
of operation
Comments - Place Fill port at 12 o'clock position and Check
port at 8 o'clock position. Pour lubricant into fill port until it
just starts to flow out of check port.
1200 hours
3121170

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents