Download Print this page

EdilKamin TINY Installation, Use And Maintenance Manual page 54

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 30
TROUBLESHOOTING TIPS FOR TINY
5) Black Out: (not a defect of the stove).
Turns off due to lack of electricity
Check electricity connection and drops in voltage.
6) Fault/RC: (intervenes if the thermo coupling has failed or is disconnected).
Turns off due to thermo coupling failed or disconnected
Check connection of thermo coupling to board: check function in cold test.
7) smoke °C/high: turns off due to exceeding maximum smoke temperature.
Excessive smoke temperature may depend on: pellet type, anomaly in smoke extraction, smoke channel blocked,
incorrect installation, gear motor 'drift'
Remote control inefficient:
• closer to the receiver of the stove
• check the battery and if necessary, replace it
Output air not hot:
• clean the hearth exchanger.
During ignition, the differential switch trips (DEALER):
• check moisture content of ignition resistance
Does not ignite:
• clean combustion chamber.
"Battery check":
• The stove does not stop but the error appears on the display.
• The buffer battery of the control board needs changing.
NOTA 1
All signals/warnings remain shown until you intervene on the remote control, by pressing the button
Do not use the insert before having eliminated the problem.
NOTA 2
After 1000 kg of pellets consumed, the display flashes the wording 'Mainten.'.
The stove works, but you must call the Dealer out to perform extraordinary maintenance.
54
.

Advertisement

Chapters

loading

This manual is also suitable for:

Kelly