Download Print this page

EdilKamin TINY Installation, Use And Maintenance Manual page 33

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 30
The TINY pellet stove is equipped with SISTEMA LEONARDO
LEONARDO
®
is a combustion safety and control system which allows optimal performance in all
conditions.
This is a safety system that allows optimum operation in all conditions.
LEONARDO
®
ensures excellent operation thanks to two sensors measuring the pressure level in the combustion
chamber and smoke temperature. The detection of and subsequent optimisation of these two parameters is continuous
in order to correct operation anomalies in real time.
The LEONARDO
®
system offers constant combustion, automatically regulating the draft based on the characteristics
of the chimney flue (bends, length, shape, diameter, etc.) and environmental conditions (wind, humidity, atmospheric
pressure, installations at high altitude, etc.). The standards for installation must be respected.
LEONARDO
®
system is also able to recognise the type of pellets and automatically adjust the flow moment by
moment to ensure the required level of combustion.
ELECTRONIC CIRCUIT BOARD TINY
wiring diagram
RS232/AUX
M
M
N
N
SOS
AUX
SMOKE RPM
F
F
R
R
RS232/485
SERVICE
BACKUP
BATTERY
LITHIUM
CR2032
D
A
D
A
Smoke expulsion
motor
F
F
TM 150 °C
VENTILATION
M SCREW
SERIAL PORT
The Dealer can install an optional on the AUX outlet for controlling the process of switching on and off (e.g. telephone
remote, local thermostat), located at the rear oh the stove.
Can be connected via special optional trestle (TINY code 621240 - KELLY code 620550).
The serial port is located inside the stove on the lefthand side.
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032 battery).
Its failure (not considered a product defect, but normal wear and tear) is indicated with the words "Battery check" for
the TINY model and "Batt. 1 - Batt. 2" for the KELLY model.
For more detailed information, please contact the DEALER who has performed the first 1st ignition.
ROOM TEMPERATURE SENSOR
An outlet for the 1 metre-long room temperature cable is provided on the back of the stove.
The sensor, which will be attached to the wall using the bracket provided, is wired onto the end
of the cable.
FEATURES
G
G
L
H
L
H
FLOW
SENSOR
IN
J
SENSOR AIR
Vacuum gauge
AMBIENT (optional)
P2
P1
Reading
points
P
P
C
B
B
C
INGNITION ELEMENT
230 Vac POWER SUPPLY
50-60 Hz +/-10%
33
®
.
ELECTRONIC CIRCUIT BOARD KELLY
wiring diagram
SMOKE THERMOCOUPLE
SMOKE RPM
IN T° J
RS232
FLOW
SENSOR
M SCREW
Smoke expulsion
VENTILAZIONE
motor
TM
TM
Legenda:
SENSOR AIR AMBIENT
SENSOR AMBIENT
I/O CONSOLLE
CONSOLLE
BACKUP
BATTERY
LITHIUM
CR2032
230 Vac power supply
50 Hz +/-10%
INGNITION ELEMENT

Advertisement

Chapters

loading

This manual is also suitable for:

Kelly