Figure 030-15: Heat-Flow Temperature Sensor Housing - Miele DGC 6 Series Technical Information

Table of Contents

Advertisement

Technical Information

Figure 030-15: Heat-Flow Temperature Sensor Housing

11. Remove the seal from the temperature sensor, and release the
temperature sensor from its housing.
12. Disconnect the green-and-yellow ground wire from the temperature
sensor, and then disconnect the red-and-white wiring harness from the
power electronic.
Note:
The seal will be damaged during removal and must be replaced.
13. Install a new seal; see Figure 030-16, Item 1.
Note:
When installing the temperature sensor, always press against the seal;
otherwise, the seal will be damaged.
14. Install the temperature sensor; see Figure 030-16, Item 2.