Fascia Panel Is Crooked; Float Stuck In Water Tank; Fascia Panel Does Not Respond When Sensor Is Pressed - Miele DGC 6 Series Technical Information

Table of Contents

Advertisement

Technical Information
3.7

Fascia Panel Is Crooked

Symptom:
In the closed position, one side of the panel is not resting against the
appliance front. In the open position, the panel is not level.
Cause:
Gears are positioned unequally in the guide rails.
Remedy:
Position the gears equally in the guide rails.
3.8

Float Stuck in Water Tank

Symptom:
Float(s) and chamber cover are stuck in the water tank.
Cause:
Inadequate adhesion between float chamber and cover.
Series modification:
None at the moment. The welding technique for adhering the cover to the
float chamber has been improved. The chamber has also been enlarged in
order to prevent the float from jamming. Series modification effective after
machine no. 111340154.
Remedy:
Replace the water tank.
Note:
The inventory in the replacement-parts warehouse has been simplified so
that now only the improved water tank is available.
Install a water tank with the following material numbers (or higher):
3.9

Fascia Panel Does Not Respond When Sensor Is Pressed

Symptom:
Fascia panel does not respond when sensor is pressed. A confirmation tone
can be clearly heard, but the fascia panel will not open or close.
Cause:
Software fault. If the fascia panel is closed and then a sensor is pressed
within the next half-second, this creates an undefined condition in the
software.
Series modification:
New firmware update, ID 2531 to 2534.
Remedy:
1. Firmware update to ID 2531 or higher.
Water tank: mat. no. 8577101 (check the parts CD first)
Condensate tank: mat. no. 8577081 (check the parts CD first)
62
DGC 6xxx

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dgc 6500Dgc 6600Dgc 6700Dgc 6800Dgc 6705Dgc 6805

Table of Contents