Technical Information
4. Make sure that the antenna wiring is secure.
5. Make sure that the roast probe (EPI) electronic's wiring is secure.
6. Make sure that the top heating element is not deformed.
7. Make sure that the antenna is not deformed.
8. Make sure that the wireless roast probe is not deformed.
9. Make sure that the door closes correctly.
10. Test the wireless roast probe; see Section 045-4.12.
4

Service

4.1

Cooling-Fan (M2-1) Removal

1. Remove the appliance from its housing unit; see Section 010-4.1.
2. Disconnect the appliance from the power supply.
3. Remove the lid; see Section 010-4.2.
4. Remove the rear/left side panel; see Section 010-4.4.
5. Remove the two T20 screws securing the distributor behind the fan. See
arrows, Figure 045-4.

Figure 045-4: Distributor behind Cooling Fan

6. Remove the two T20 screws securing the cooling fan to the air duct; see
Figure 045-5, Item 1.