Figure 040-1: Leaf Springs on Telescopic Rails

Note:
Replace all four leaf springs to ensure correct positioning.
3.12

Guide Rail End Stoppers Difficult to Install

Symptom:
The guide rail end stoppers are very difficult to install.
Cause:
-
Remedy:
Install the new guide rails. See the parts CD for current part numbers.
3.13

Fascia Panel Installed at an Angle

Symptom:
In the closed state, the fascia panel does not align with the appliance front on
one side. In the open state, it is not level.
Cause:
The cog wheels have been positioned unevenly in the guide rails.
Remedy:
Position the cog wheels evenly in the guide rails.
3.14

"Remove Roast Probe"

Symptom:
The presence of the roast probe in the cavity has been registered even
though it is not there.
Cause:
Fault in the wireless roast probe system.
Remedy: