Technical Data; Function; Heat-Flow Temperature Sensor (2R30-10); Fault Repair - Miele DGC 6 Series Technical Information

Table of Contents

Advertisement

Technical Information
1

Technical Data

Power rating
Temperature monitor 3F1
switching point
Temperature monitor 1F1
switching point

Table 030-1: Heater Element Data

Oven lights (1H3-2, 2H3-2)
Voltage
Power rating
Temperature resistance limit

Table 030-2: Oven Light Data

Temperature [°F]
32
68
77
86
122
212
302
392
482
572

Table 030-3: Heat-Flow Temperature Sensor Resistance Chart

2

Function

2.1

Heat-Flow Temperature Sensor (2R30-10)

The Pt1000 temperature sensor is a platinum sensor. Its resistance increases
proportionally with the temperature in the cavity; see Table 030-3.
3

Fault Repair

3.1

Cavity Surface Scratched

Cause:
A cleaner unsuitable for use with PerfectClean was used.
Remedy:
Do not clean the cavity with abrasive cleaning agents; see the operating
instructions.
Convection
(R14)
1750W
482°F
158°F
12V
2 x 20W
572°F
Heat-flow Pt1000 temperature sensor (2R30-10)
Resistance [Ω] (in accordance with DIN EN 60751)
28
Heater element
Top (R13)
Broil (R15)
1100W
800W
482°F
482°F
158°F
158°F
1000
1078
1097
1117
1194
1385
1573
1758
1941
2120
DGC 6xxx
Bottom (R12)
700W
248°F (2F1)
158°F