Fault Code F192 - Heat-Flow Pt1000 Temperature Sensor Open-Circuited; Fault Code F193 - Bottom Heat Pt1000 Temperature Sensor Short-Circuited; Fault Code F194 - Bottom Heat Pt1000 Temperature Sensor Open-Circuited; Fault Code F195 - Roast Probe Electronic Communication Fault - Miele DGC 6 Series Technical Information

Table of Contents

Advertisement

Technical Information
3.15
Fault Code F192 - Heat-Flow Pt1000 Temperature Sensor Open-
Circuited
Cause:
Temperature sensor (2R30-10) or wiring harness open-circuited.
Remedy:
1. Check the wiring harness.
2. Replace the heat-flow temperature sensor with its wiring harness. See
Section 030-4.9.
3.16
Fault Code F193 - Bottom Heat Pt1000 Temperature Sensor Short-
Circuited
Cause:
Temperature sensor (R30/22) or wiring harness short-circuited.
Remedy:
1. Check the wiring harness.
2. Replace the bottom heater element temperature sensor with its wiring
harness. See Section 030-4.4.
3.17
Fault Code F194 - Bottom Heat Pt1000 Temperature Sensor Open-
Circuited
Cause:
Temperature sensor (R30/22) or wiring harness short-circuited.
Remedy:
1. Check the wiring harness.
2. Replace the bottom heater temperature sensor with its wiring harness.
See Section 030-4.4.
3.18
Fault Code F195 – Roast Probe Electronic Communication Fault
Cause:
Wiring/plugs between roast probe electronic (N1-6) and power electronic (N1-
1) defective.
Remedy:
Check the plug for correct seating and contact. Check wiring. Replace
defective wiring with plugs.
Cause:
Roast probe electronic (N1-6) defective.
Remedy:
Install a new roast probe electronic (N1-6); see Section 045-4.11.
Cause:
Power electronic (N1-1) defective.
Remedy:
Install a new power electronic. See Section 045-4.8.