Zone Definitions - DSC Envoy NT9005EU Installation & Programming Manual

32 zone security system
Table of Contents

Advertisement

05
Interior Stay/Away - This zone works the same as the
Interior zone type except that the zone will be bypassed
under the following conditions:
- the system is armed in Stay mode.
- the system is armed without entry delay.
- the system is armed with an access code and during the
exit delay, a Delay zone is NOT tripped.
The automatic bypass avoids having the user manually
bypass interior type zones when arming at home. If auto-
matically bypassed, the user can reactivate the zones by
entering the [*][1] command (see [*][1] Zone Bypass-
ing. Typically this zone type is used for interior protection
devices such as motion detectors.
06
Delay Stay/Away This zone will operate the same as
the Interior Stay/Away zone except that it will always
provide entry delay. Typically this zone is used for interior
protection devices such as motion detectors and will help
prevent false alarms since it will always provide the user
with the entry delay time to turn off the system.
07-09 Future Use
10
24-Hr Supervisory Buzzer - This zone is active at all
times and will report an alarm at all times. When tripped
the keypad buzzer will sound until a valid access code is
entered.
Do NOT use on a keyswitch only system.
11
24-Hr Burglary - This zone is active at all times and will
report an alarm if armed or disarmed. This zone will
sound the bell for the length of Bell Cutoff if the audible
attribute is enabled.
12
24-Hr Holdup - Similar to 24-Hr Burglary except for Sys-
tem Event output type and SIA identifier.
This zone gives a silent alarm by default
13
24-Hr Gas - Similar to 24-Hr Burglary except for System
Event output type and SIA identifier.
14
24-Hr Heat - Similar to 24-Hr Burglary except for System
Event output type and SIA identifier.
15
24-Hr Medical - Similar to 24-Hr Burglary except for Sys-
tem Event output type and SIA identifier.
16
24-Hr Panic - Similar to 24-Hr Burglary except for System
Event output type and SIA identifier.
17
24-Hr Emergency. - Similar to 24-Hr Burglary except for
System Event output type and SIA identifier.
18
24-Hr Sprinkler - Similar to 24-Hr Burglary except for
System Event output type and SIA identifier.
19
24-Hr Water - Similar to 24-Hr Burglary except for Sys-
tem Event output type and SIA identifier.
20
24-Hr Freeze - Similar to 24-Hr Burglary except for Sys-
tem Event output type and SIA identifier.
firealarmresources.com
[001]-[004] Zone Definition
21
24-Hr Latching/Tamper - If this zone is violated, the sys-
tem will not arm until [*][8][Installer's Code] is entered.
22
Momentary Keyswitch Arm - Momentary violations of
this zone will alternately arm/disarm the system.
Do not use with wireless zones.
23
Maintained Key Switch Arm - When zone is violated,
the system will arm. When zone is secured, the system
will disarm.
NOTE: Do not use with wireless zones.
24
Future Use
25
Interior Delay - When the system is fully armed (i.e.,
Away Armed) this zone will follow exit delay. It will also
follow the entry delay, provided that the delay zone is
tripped first; otherwise it will go into alarm instantly.
When the system is Stay Armed, this zone will be active,
but when it is tripped, it will initiate the entry delay.
26
24-Hr Non-Alarm Zone - This zone does not sound a
bell, nor transmit any alarm condition to the central sta-
tion. Can be used to sound the door chime.
28
24-Hr Bell/Buzzer Zone - This zone operates like a 24-
Hr Burglary when armed and like a 24-Hr Supervisory
Buzzer when disarmed.
29
Instant Stay/Away - This zone will operate the same as
the Interior Stay/Away zone except that it will cause an
instant alarm when not bypassed.
87
Delay 24-Hr Fire (Wireless) - Used only with wireless
smoke detectors.Delayed 24-Hr Fire (Wireless) works the
same way as the standard fire zone, except the alarm
memory and transmission by the communicator is
delayed by 30 seconds. If the alarm is acknowledged by
pressing any key within 30 seconds, the bells will silence
and the transmission will be aborted. After the alarm has
been acknowledged, and the smoke detector has not
been restored to normal, after 90 seconds the bell output
will be activated again; the user then has another 30 sec-
ond delay before the bell output latches and communica-
tions is activated. A code would then be required to
silence the bell output.
The Fire Delay will be terminated if a 2nd fire zone is
tripped or if the [F] key is pressed during a delay.
88
Standard 24-Hr Fire (Wireless) - Used only with wire-
less smoke detectors. On alarm, the bell output will
sound to indicate that the fire loop has been activated. If
enabled, the communicator will immediately transmit the
alarm to the monitoring station.
Do NOT change the
Attributes on Fire type zones.
default settings for Zone
23