Pc5204 Pgm Output Programming; Keypad Lockout Options; First System Options; Second System Options - DSC PowerSeries PC1404 Installation Manual

V1.0
Hide thumbs Also See for PowerSeries PC1404:
Table of Contents

Advertisement

PC1404

[011] PC5204 PGM Output Programming

Default
01
I_______I_______I
01
I_______I_______I
01
I_______I_______I
01
I_______I_______I

[012] Keypad Lockout Options

Note: If Keypad Lockout is active, the panel CANNOT be disarmed with a keyswitch.
Default
000
Number of Invalid Codes Before Lockout
I_______I_______I______I
000
Lockout Duration (in minutes)
I_______I_______I______I

[013] First System Options

Opt. Def.
ON
1
Normally Closed Loops
2
Double End-of-Line Resistors
3
Panel Shows All Troubles While Armed
4
Tampers/Faults Do Not Show as Open
5
Auto-Arm Schedule in [
6
Audible Exit Fault Enabled
7
Zone Doubling Enabled
8
Temporal Three Fire Signal Enabled
Note: When Option 7 is ON, the configuration of Options 1 and 2 should be ignored.

[014] Second System Options

Opt. Def.
ON
1
Arm/Disarm Squawk Enabled
2
Bell Squawk During Auto Arm On
3
For Future Use
4
For Future Use
5
For Future Use
6
For Future Use
7
Exit Delay Termination Enabled
8
Fire Bell is Continuous

[015] Third System Options

Opt. Def.
ON
1
[F] Key Enabled
2
[P] Key Audible (Bell/Beeps)
3
Quick Exit Enabled
4
Quick Arming Enabled ([,][0] and Function Keys)
5
Code Required for Bypassing
6
Master Code Not Changeable
7
TLM Enabled
8
For Future Use

[016] Fourth System Options

Opt. Def.
ON
1
 
AC Trouble Displayed
2
Trouble Light Flashes if AC Fails
3
Blank Keypad When Not Used
4
Code Required to Remove Keypad Blanking
18
PGM 11
PGM 12
PGM 13
PGM 14
][6] + Installer Prog.
*
(Valid entries are 000-255)
(Valid entries are 000-255)
OFF
End-of-line Resistors
Single End-of-line Resistors
Panel Shows Fire Troubles While Armed
Tampers/Faults Show As Open
Auto-Arm Schedule in Installer Prog. Only
Audible Exit Fault Disabled
Zone Doubling Disabled
Standard Pulsed Fire Signal
OFF
Arm/Disarm Squawk Disabled
Bell Squawk During Auto Arm Off
Exit Delay Termination Disabled
Fire Bell Follows Bell Cut-off
OFF
[F] Key Disabled
[P] Key Silent
Quick Exit Disabled
Quick Arming Disabled (Function Key Requires Code)
No Code Required
Master Code Changeable
TLM Disabled
OFF
AC Trouble Not Displayed
 
Trouble Light Does Not Flash if AC Fails
 
Keypad Always Active
 
No Code Required

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents