Table Of Contents - DSC Envoy NT9005EU Installation & Programming Manual

32 zone security system
Table of Contents

Advertisement

Table of Contents

1-1 System Overview . . . . . . . . . . . . . . . . . . . . . 1
1-2 System Specifications . . . . . . . . . . . . . . . . . 2
1-3 Modules and Devices . . . . . . . . . . . . . . . . . . 3
1-4 NT9005 Label & Console . . . . . . . . . . . . . . 4
1-5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Chapter 2: Installation . . . . . . . . . . . . . . . . 7
2-1 Installation Procedure. . . . . . . . . . . . . . . . . . 7
2-2 NT9005 Installation . . . . . . . . . . . . . . . . . . . 8
2-3 System Wiring . . . . . . . . . . . . . . . . . . . . . . . 9
2-4 Wireless Device Placement . . . . . . . . . . . . 11
Chapter 3: Programming . . . . . . . . . . . . . 12
3-1 Programming Overview . . . . . . . . . . . . . . . 12
IMPORTANT:
1. This Manual shall be used in conjunction with the Installa-
tion Manual of the used Power Supply (NT9005 Trans-
former Kit - AC/AC Adaptor).
2. This equipment, Alarm Controller NT9005 shall be
installed and used within an environment that provides
the pollution degree max 2 and overvoltages category II
NON HAZARDOUS LOCATIONS, indoor only. The equip-
ment is FIXED and PERMANENTLY CONNECTED and is
designed to be installed by service persons only; [service
person is defined as a person having the appropriate tech-
nical training and experience necessary to be aware of
hazards to which that person may be exposed in perform-
ing a task and of measures to minimize the risks to that
person or other persons.].
3. The connection to the mains supply must be made as per
the rules and regulations of the local authorities: In the
UK as per BS6701. An appropriate disconnect device
must be provided as part of the building installation.
Where it is not possible to rely on the identification of the
NEUTRAL in the AC MAINS SUPPLY, the disconnecting
device must disconnect both poles simultaneously (LINE
and NEUTRAL). The device shall disconnect the supply
during servicing.
OPERATING instructions shall be made available to the USER.
3-2 Conventions Used . . . . . . . . . . . . . . . . . . . 12
3-3 [*] Functions . . . . . . . . . . . . . . . . . . . . . . . 13
5-1 Section Overview . . . . . . . . . . . . . . . . . . . . 20
Appendix A: Reporting Codes . . . . . . . . 47
Placement. . . . . . . . . . . . . . . . . . . . . . . . . 50
Appendix D: WLS904P Wireless
Motion Detector . . . . . . . . . . . . . . . . . . . . 52
4. Equipment enclosure must be secured to the building
5. Regarding the power supply it must be permanently con-
6. Internal wiring must be routed in a manner that prevents:
7. Disposal of the used batteries shall be made according to
8. Disconnect the TELEPHONE CONNECTION before servic-
firealarmresources.com
structure before operation.
nected, fail safe, with double or reinforced insulation
between primary and secondary circuits. In EU countries it
must meet the applicable requirements of the Low Volt-
age Directive and protected as per the EN60950-1: 2001
Standard requirements. In all other countries, it must be
of an approved type acceptable to the local authorities.
• Excessive strain on wire and on terminal connections;
• Loosening of terminal; connections;
• Damage of conductor insulation.
the waste recovery and recycling regulations applicable to
the intended market.
ing!

Advertisement

Table of Contents
loading

Table of Contents