[07] Keypad Lockout Options

This section determines how the Keypad Lockout function operates. The first number determines how many
invalid Access Codes need to be entered to lockout the keypad; enter a 2-digit number from 00 to 99.
The second number determines how long, in minutes, the keypad will be locked out. Enter a 2-digit number from
00 to 99. Programming either of the numbers in the section as 00 will disable the keypad lockout feature.

[08] First System Option Code

The First System Option Code is set using the Zone Lights as shown in the table below. Once Section [08] is
entered, the 8 Zone Lights will indicate the status of each option. Press the number key corresponding to the
Zone Light to turn an option ON and OFF. Press [0] to turn all the Zone Lights OFF.
Zone Light 1: Zone Loop Options
ON: Normally Closed Zones. All zones are wired as normally closed circuits with return to a COM terminal.
An alarm will be generated when the circuit is opened.
• OFF: End-of-Line Resistor Zones. All zones must be wired with an end-of-line resistor connected between the
ZONE and COM terminals. An alarm will be generated when the circuit is opened or shorted. If the zone
is programmed as a Fire Zone, an open circuit will be reported as a Fire Trouble, and a short circuit will
be reported as a Fire Alarm.
Zone Light 2: Zone Power-up Options
• ON: 120-second Bypass on Power-up. When power is first applied to the system, all zones will be bypassed
for two minutes. This is to allow time for the detection devices to "settle" without causing false alarms.
After 2 minutes, the zones will be active.
OFF: Zones Active on Power-up. All zones will be active when power is applied to the system.
Zone Light 3: Auxiliary Delay Zones Force Arming Option
ON: Force Arming on Auxiliary Delay Zones. The system may be armed with Auxiliary Delay Zones being left
open. When the system is armed, the Auxiliary Delay Zones will be bypassed. When the zones are
secured, they will be added to the system and will be armed. Once armed, activity on an Auxiliary Delay
Zone will initiate the Auxiliary Entry Delay.
• OFF: No Force Arming. If an Auxiliary Delay Zone is left open when the system is armed, the Auxiliary Entry
Delay will begin as soon as the Exit Delay expires. If the system is not disarmed before the Auxiliary
Entry Delay expires, an alarm will be generated.
Zone Light 4: Partial Closing Reporting Option
ON: Partial Close on Auto-Arm. When the system is Auto-armed with open zones, the system will transmit the
Partial Closing Code and the User Closing Code.
• OFF: No Partial Close on Auto-Arm. When the system is Auto-armed with open zones, the system will only
transmit the User Closing Code.
Zone Light 5: Quick-Exit Enable / Disable
ON: Quick-Exit Enabled. With the system armed in the Home-Away mode, users may enter the [
Command to allow a single Delay Zone to be activated so they may leave the premises. Only one Delay
Zone may be activated; any additional activity on another Delay Zone will generate an alarm. If the Delay
zone is still open two minutes after the [
• OFF: Quick-Exit Disabled.
Zone Light 6: PC16OUT Options
ON: PC16OUT Module Enabled. A PC16OUT module may be connected to the control panel; refer to the
PC16OUT Installation Sheet.
• OFF: PC16OUT Module Disabled. The system will not support the use of a PC16OUT Module.
Zone Light 7: AC Trouble Options
ON: AC Excluded from Trouble. If AC power fails, the condition will be reported to the monitoring station but
will not be indicated on the system keypads.
• OFF: AC Trouble Reported and Displayed. If AC power fails, the condition will be reported to the monitoring
station and will be indicated as a Trouble condition on the system keypads.
Zone Light 8: For Future Use
• OFF: Zone Light 8 is not used and is reserved for future use. Zone Light 8 must be OFF at all times.
• Factory default setting
][0] command is entered, the Entry Delay will be initiated.
][0]