Misc. Closing (Arming) Reporting Codes; Misc. Opening (Disarming) Reporting Codes; Maintenance Alarm Reporting Codes; Maintenance Restoral Reporting Codes - DSC Envoy NT9005EU Installation & Programming Manual

32 zone security system
Table of Contents

Advertisement

Advanced Programming

[343] Misc. Closing (Arming) Reporting Codes

These codes are sent to the System Openings and Closings Call
Direction Group programmed in section [365].
I___I___I
Closing By Duress Code 33
The Duress Alarm programmed in section [328] Entry[1] is
also sent.
I___I___I
Closing By Duress Code 34 - See above.
I___I___I
Closing By System Code 40
I___I___I
Closing By System Code 41
I___I___I
Closing By System Code 42
I___I___I
Partial Closing
I___I___I
Special Closing
I___I___I
Late to Close

[348] Misc. Opening (Disarming) Reporting Codes

These codes are sent to the System Openings and Closings Call
Direction Group programmed in section [365].
I___I___I
Opening By Duress Code 33
The Duress Alarm programmed in section [328] Entry[1] is
also sent.
I___I___I
Opening By Duress Code 34 - See above.
I___I___I
Opening By System Code 40
I___I___I
Opening By System Code 41
I___I___I
Opening By System Code 42
I___I___I
Auto-arm Cancellation
This code is sent when the Auto-arm sequence is cancelled by
entering an access code or by pressing the Disarm key on a
wireless key during the one minute pre-alert.
I___I___I
Special Opening

[349] Maintenance Alarm Reporting Codes

These codes are sent to the System Maintenance Alarms and Resto-
rals Call Direction Group programmed in section [367].
I___I___I
Battery Trouble Alarm
This code is sent when the battery voltage is low or battery is
disconnected.
I___I___I
AC Failure Trouble Alarm
This code is sent If the AC supply fails. This code is sent after
the delay programmed in section [370] entry 9.
I___I___I
Future Use
I___I___I
Future Use
I___I___I
Future Use
36

[350] Maintenance Restoral Reporting Codes

These codes are sent to the System Maintenance Alarms and
Restorals Call Direction Group programmed in section [367].

[351] Misc. Maintenance Reporting Codes

These codes are sent to the System Maintenance Alarms and
Restorals Call Direction Group programmed in section [367].
firealarmresources.com
I___I___I
Future Use
I___I___I
General System Trouble
This code is sent to report miscellaneous system troubles not
reported individually. The first alarm will initiate commnunica-
tions. Possible causes of this are:
NT9204 - AC Trouble / Restoral
- Battery Trouble / Restoral
- Supervised Output Circuit Trouble / Restoral
NT9005 -RF Jam Detection for a duration of 30 seconds
or 5 minutes.See section [018] option [2]
I___I___I
General System Supervisory
This code is sent if the system has lost communications to an
enrolled module, or a Keybus fault has been detected. The
first alarm will initiate the communications.
I___I___I
Battery Trouble Restoral
I___I___I
AC Failure Trouble Restoral
I___I___I
Future Use
I___I___I
Fire Trouble Restoral
I___I___I
Future Use
I___I___I
TLM Restoral
I___I___I
General System Trouble Restore - This code
is sent on the last restoral
I___I___I
General System Supervisory Restore - This
code is sent on the last restoral
I___I___I
Telephone #1 FTC Restore
If events fail to communicate to either telephone number, this
code will be sent on the next successful communication. The
information will be transmitted in the following order.
- Old Event(s)
- Failure To Communicate (Telephone #1)
- New Event(s)
If multiple FTCs occur, this code will create blocks of old
information.The FTC reporting code is sent to every group's
call directions upon transmissions of failed event transmis-
sions. When event(s) fail to communicate to a telephone
number, there will not be an attempt to communicate again
until another event is sent to that phone number.
I___I___I
Telephone #2 FTC Restore - See option 1
I___I___I
Event Buffer 75% Full

Advertisement

Table of Contents
loading

Table of Contents