teko Astra-5 Ver.A Operation Manual page 2

Optic-electronic pir motion detector

Advertisement

6 Information Capacity
Table 1 – Events and notifications to indicator and relay
Event type
Indicator
Starting of
Flashes 1 time per 1s
detector
after power up.
stand-by
Duration up to 60s
mode
Norm
Lights up 1 time for 4s
at detection of man
Alarm
movement in detection
zone (when indication is
enabled)
Alarm in the
"Alarm
Figure 4
memory"
mode
Lights up 1 time for 2s
Alarm during
at detection of man
test-pass
movement in detection
zone
Keeps lighting until fail-
Failure
ure elimination
Tampering
relay is open,
relay is closed,
TMP circuit is open
7 Operation Modes
Table 2 – Operation modes and settings
Operation mode
High detectability
Normal detectability
Indication ON
Indication OFF
"Alarm memory" ON
"Alarm memory" OFF
TEST-pass
(Switches ON for 8
min.)
"+" -
jumper is installed on both plug pins
"-" –
jumper is removed (or installed on one plug pin)
Relay
During up to
60s
Not lit
Relay opens for
4s
Relay works in
common mode
Relay opens for
2s
Relay is open
until failure eli-
mination
Not lit
TMP relay is
open
Number of alarm
Reiterated indication
events (up to 3)
Figure 4
Plug name
Jumper position
+
Sens
+
Ind
+
Mem
For a short mo-
ment (for 2-3s)
change jumper
position on the
Ind
plug Ind during
starting of detec-
tor operating
mode
The "Alarm memory" mode allows registering the fact
and number of zone violations in prortected area, and is
reflected in corresponding notification .
The mode is activated in 1 minute after installation of Mem
plug or in 1 min. after starting of detector stand-by mode with
jumper installed previously on Mem plug. "Alarm" notification
is indicated in 1 min. after violation of protected area. To
switch the mode off and reset indication, remove jumper from
Mem plug or switch power off.
TEST-pass allows revealing precise location of sensitive
zones formed by the lens. On expiry of 8 min the detector
automatically starts its stand-by mode.
8 Installation and Pre-starting Procedure
8.1
Works on installation, mounting, maintenance and
operation of detector should be performed by only qualified
persons.
8.2
After transportation in conditions differing from those of
operation keep detector unpacked under supposed operation
conditions for at least 4 hours.
8.3 Selection of Installation Place
8.3.1 Recommended height of installation
8.3.2 In capital buildings it is recommended to install
detector on a bearing wall.
8.3.3 In light metalwork buildings one should avoid to install
detector directly on the wall, it is recommended to install
detector on bearing carriers.
8.3.4 Wires of signaling zones and power supply circuits should
be located far from power cables.
8.3.5 It is recommended to close all doors, air-vents, switch
off fans, air-conditioners and other sources of intense air flows
in the room during protection period.
8.3.6 It is not recommended to install detector in the
following places.
2
m
5-av8_2_en