teko Astra-5 ver.A User Manual

Optic-electronic pir motion detector

Advertisement

Quick Links

"Astra-5 ver. A"
Optic-Electronic PIR
Motion Detector
(Volumetric Lens)
User Guide
Manufacturer:
ZAO NTC TEKO
420108 Kazan, Russia
Gafuri 71
+7843 528-03-69
export@teko.biz
www.teko.biz
Made in Russia
Rev. 5-av2_1_instr_en
1 FUNCTION
Detector is intended to detect unauthorized
access into closed protected area and to
generate an alarm notification
signaling relay output
contacts.
2 DETECTION ZONE
3 SPECIFICATION
Range of detectable
moving speed, m/sec
............. from 0.3 up to 3.0
Power supply voltage, V ............. from 9 up to 15
Current consumption, mA, max ......................12
Overall dimensions, mm ................. 78 × 63 × 44
Operating Conditions
Temperature range, °С ........ from - 30 up to +55
Relative air humidity, % ........... up to 98 at +25 °С
Without moisture condensation
4 DELIVERY SET
Delivery set includes: dowel – 2 pcs., screw – 2
pcs., bracket – 1 pc., user guide – 1 pcs., label
– 2 pcs.
by opening
5 INDICATION
Notifications
Boot time
Norm
Alarm
Failure
Tampering
" – relay closed, "
"
opened, ТМР
In the factory setting, the "alarm" indication is
permanently enabled.
ATTENTION! When the detector power is re-
set, the factory setting of the indication mode is
automatically restored.
LED
Relay/ТМР
Flashes 1 time
per 1 sec after
for 60 sec
powering until
60 sec
Off
Lights up 1 time
for 2 sec during
movement is
detected in the
for 2 sec
detection zone (if
indication is
allowed)
Lights up until
the failure is
until the failure
eliminated
is eliminated
ТМР
Off
" – relay
– ТМР relay opened

Advertisement

loading

Summary of Contents for teko Astra-5 ver.A

  • Page 1 User Guide Failure the failure is until the failure eliminated is eliminated ТМР Tampering Manufacturer: ZAO NTC TEKO " – relay closed, " " – relay 3 SPECIFICATION " 420108 Kazan, Russia opened, ТМР – ТМР relay opened Range of detectable In the factory setting, the “alarm”...
  • Page 2 Changing the indication mode of “Alarm” is 7 INSTALLATION PROCEDURE 8 WIRING made by closing the Ind contact for at least 10 Perform wiring to detector`s terminals in 1) Open the sec. accordance with control panel operating detector by pushing manual.