The present operation manual is intended for studying operation
principle, running conditions and maintenance of PIR motion
detector Astra-5 ver.A (hereinafter "detector") (Figure 1).
The manufacturer reserves the right to make alteration
regarding refinement of the product without prior notification. All
changes will be imported into new edition of the operation
manual.
1 Function
1.1
Detector
is
intended
unauthorized
access
protected area, and to generate an alarm
notification
by opening of alarm relay
contacts.
1.2
Power
supply
of
performed from any direct current source
with nominal voltage 12V and pulsation
amplitude not exceeding 0,1V.
2 Principle of Operation
Operation principle is based on
registration
of
changes
thermal emission flux occurring
on crossing by a man of
detection zone consisting of
sensitive
zones.
sensitive zone consists of two
elementary
sensitive
zones
(figure 2).
Detector sensitive zones are
formed by Fresnel lens and bi-
areal
pyroelectric
radiation
reciever.
Pyroelectric
reciever
sends
electric
signal
microcontroller, which in its
turn
generates
an
"Alarm"
notification in accordance with
pre-set algorithm by opening
optoelectronic relay circuit.
3 Specification
Technical Parameters of Optical Channel
Detection range, m, not exceeding ............................................ 12
Detection area volume
with viewing angle in horizontal plane 90° ...................... 12×12
Range of detected
moving speed, m/s ....................................... from 0,3 up to 3,0
Resistance to ambient light, lx, not less than ................... 6500
Recommended installation height, m............ from 2,4 up to 2,5
General Technical Parameters
Power supply voltage, V ................................... from 8 up to 15
Current consumption in stand-by mode and
in "Alarm" mode, mA, not exceeding .................................... 12
Relay contacts permissible current, A, not exceeding ....... 0,08
Permissible voltage on relay
contacts, V, not exceeding ................................................. 100
Permissible TMP circuit current, A, not exceeding ............ 0,05
Permissible TMP circuit voltage, V, not exceeding ............... 72
Resistance of circuit connected to signaling zone,
in stand-by mode, Ohm ...................................... from 6 up to 8
Overall dimension, mm, not exceeding..................... 75×58×48
Weight, kg, not exceeding ............................................... 0,053
Astra-5 Ver.A (Volumetric Lens)
Optic-Electronic PIR Motion Detector
Operation Manual
to detect
into
closed
detector
is
Figure 1
in
Each
to
Figure 2
Operating Conditions
Temperature range, °C ................................ from -30 up to +50
Relative air humidity,% ..................................... up to 95 at + 35 °С
4 Delivery Set
PIR motion detector Astra-5 ver.A
Screw 2.9x25 (or 2-3x30) ................................................. 2 pcs
Dowel 5x25 ...................................................................... 2 pcs
Sealing material................................................................ 1 pcs
User Instruction .............................................................. 1 copy
5 Structure
Detector is designed as a unit consisting of a base and
removable cover. Printed circuit-board with radioelements and
screw terminal block for outside connections is mounted
inside the unit (figure 3).
There is a button – tamper switch - on the circuit-board that
generates alarm notification at the cover removal irrespective-
ly of detector power up.
Detector operability indicator for operation capability control is
installed on the printed board.
From the inner side of the detector's cover there is a fixing
element installed, clamping and fixing the lens.
Pyroelectric detector is equipped with a cap with reflector
which forms short-range detection zone.
ATTENTION! It is forbidden to operate detector without a
cap.
Without moisture condensation
........................................
Figure 3
1 pcs

Advertisement

loading

Summary of Contents for teko Astra-5 Ver.A

  • Page 1 Temperature range, °C ........ from -30 up to +50 principle, running conditions and maintenance of PIR motion detector Astra-5 ver.A (hereinafter “detector”) (Figure 1). Relative air humidity,% ........up to 95 at + 35 °С The manufacturer reserves the right to make alteration Without moisture condensation regarding refinement of the product without prior notification.
  • Page 2  The “Alarm memory” mode allows registering the fact 6 Information Capacity and number of zone violations in prortected area, and is Table 1 – Events and notifications to indicator and relay reflected in corresponding notification . The mode is activated in 1 minute after installation of Mem plug or in 1 min.
  • Page 3 8.4 Installation Procedure Step-8 Connect wires led to detector Step-1 Step-2 terminals convenience Push out cover lock from Unbend hooks of the base. connection terminal base slot. Remove PCB. resistor, additional Remove cover terminal RES is provided Step-9 Using sealing material of distribution kit seal hermetically wire insertion hole and other holes to protect detector from air and insects ingress Step-10...
  • Page 4 Phone: +49 (0) 203 / 393 91 188 Phone: +7 (843) 261-55-75 Fax: +49 (0) 203 / 393 91 189 Fax: +7 (843) 261-58-08 GSM: +49 (0) 178 / 218 48 22 E-mail: info@teko.biz E-mail: info@controlex.eu support@teko.biz Web: www.controlex.eu Web: www.teko.biz...