Dansensor MAP Mix 9001 ME User Manual ® 1. Introduction Dansensor® MAP Mix 9001 ME is MOCON Europe A/S´ equipment for gas mixing and monitoring of gas and pressure. Dansensor® MAP Mix 9001 ME is a proportional gas mixer especially designed for packaging machines and other industrial applications, where the gases N , CO and O...
Page 8
User Manual Dansensor MAP Mix 9001 ME ® P/N 250151-P 10/2021...
Dansensor MAP Mix 9001 ME User Manual ® 2. Safety instructions Read and understand this manual for your own safety and for the quality of the work you perform with this equipment. The following terms are used in this manual: DANGER! Describes a condition which MAY lead to mortal danger or serious injury....
Page 10
User Manual Dansensor MAP Mix 9001 ME ® P/N 250151-P 10/2021...
Dansensor MAP Mix 9001 ME User Manual ® 3. Equipment set up Gas connection WARNING! When mounting/dismounting fittings in order to change filters or connect gasses, it is very important that you hold against on the already mounted fittings to avoid damaging the existing assemblies (see Fig. 2). Fig.
Page 12
User Manual Dansensor MAP Mix 9001 ME ® WARNING! On buffer-tank versions make sure that the gas outlet is NEVER blocked or restricted in front of the buffer tank (see Fig. 4). Fig. 4. Correct placement of gas outlet valve P/N 250151-P 10/2021...
Dansensor MAP Mix 9001 ME User Manual ® Mounting of filters and gas connection fittings WARNING! ALWAYS use fittings and hoses which apply to the gasses used and to the intended use of the mixer. WARNING! In order to avoid damage to the internal parts of the gas mixer, " IN"...
Page 14
User Manual Dansensor MAP Mix 9001 ME ® Models > 400 liter/min. Mounted from the factory (A) Gas inlet Filter insert (fine) O-ring Ø12.6 x 2.4 mm Filter insers (coarse) O-ring Ø13.94 x 2.62 mm ...
Dansensor MAP Mix 9001 ME User Manual ® Electrical connection The mixer is equipped with two cables which must be connected as follows: Fig. 5. Cable connections Signal cable ALARM OUTPUT The alarm output can be connected in two different ways: Between Green (N.O.) and Yellow (COM) - relay is normally open and closes in case of an alarm.
Page 16
User Manual Dansensor MAP Mix 9001 ME ® P/N 250151-P 10/2021...
Dansensor MAP Mix 9001 ME User Manual ® 4. Control panel (A) Alarm monitoring on - the green lamp lights up when alarm monitoring is on. (B) On/off (reset) button - for alarm monitoring (gas pressure monitoring). (C) Alarm output on - the red lamp lights up when the alarm relay is activated due to missing gas pressure.
Page 18
User Manual Dansensor MAP Mix 9001 ME ® Setting 3-gas mix Use the grey scale to set the required CO ) percentage. Then read the X-value in the lower part of this scale. The setting of the green MIX scale is calculated on the basis of the expression: MIX = N divided by X.
Page 19
Dansensor MAP Mix 9001 ME User Manual ® Alarm on/off When the on/off button (B) is on, the pressure of the gases will be monitored. If the pressure on one of the gases is low, the alarm relay will be activated and the red lamp (C) will light up. The lamps "1", "2"...
Page 20
User Manual Dansensor MAP Mix 9001 ME ® P/N 250151-P 10/2021...
Page 24
User Manual Dansensor MAP Mix 9001 ME ® Type/Gasses Inlet pressure Outlet pressure [bar] [bar] 200/3 400/3 Gases , CO Mains supply 100-230 VAC Power cable without plug Power consumption Max. 20 W Flow range 25-250 l/min, 2 gas (1,5 - 15 m /h)...
Page 25
Dansensor MAP Mix 9001 ME User Manual ® Inlet filter Models ≤ 400 liter/min.: 60 μm Models > 400 liter/min.: 500 μm Indicators for Alarm monitoring on/off Low pressure on " GAS IN", " GAS IN" and " GAS IN"...
Page 26
User Manual Dansensor MAP Mix 9001 ME ® P/N 250151-P 10/2021...
Page 27