Dansensor
MAP Mix 9001 ME
®
Alarm on/off
When the on/off button (B) is on, the pressure of the gases will be monitored. If the pressure
on one of the gases is low, the alarm relay will be activated and the red lamp (C) will light up.
The lamps "1", "2" and possibly "3" now indicate the gas having low pressure.
The alarm lamp (C) keeps lighting up, even if the pressure is re-established, until the alarm has
been reset with the on/off button (B).
3-gas mixer used as 2-gas mixer
How to use the mixer for only N
1. Adjust the CO
2
2. Never mind the MIX-dial setting.
How to use the mixer for only N
1. Set the CO
-dial to 0.
2
2. Adjust the N
% on the MIX-dial : 0 ~ 0 % N
2
How to use the mixer for only CO
1. Set the CO
-dial to 0.
2
2. Adjust the CO
2
ATTENTION! Be sure that all 3 gases are connected to the right gas input number
(
,
and
Using a 3-gas mixer as a 2-gas mixer will give a smaller capacity than an
ordinary 2-gas mixer.
EN
and CO
2
2
% on the CO
-dial.
2
and O
2
2
and O
2
2
% on the MIX-dial : 0 ~ 0 % CO
).
and 10 ~ 100 % N
.
2
2
and 10 ~ 100 % CO
.
2
2
User Manual
17
P/N 250151-P
10/2021
Need help?
Do you have a question about the Mocon Dansensor MAP Mix 9001 ME and is the answer not in the manual?
Questions and answers