Prince Castle FLAME KING BROILER Install & Operation Manual page 15

Table of Contents

Advertisement

B.11 Pressure Adjustment
Pressure Adjustment
1. Make sure the unit is turned off.
2. Unplug the quick disconnect wire from valve "HI" pin and place loose connector in a wire cover.
3. Use a 3/32" Allen key to turn the outlet pressure test screw one turn counter clockwise, not more than one turn.
4. Attach a hose and manometer to the outlet pressure boss of the valve.
5. Remove regulator cover screw from the LOW outlet pressure regulator adjust tower.
6. Turn unit on.
7. Read pressure value and turn regulator screw clockwise to increase pressure and counter-clockwise to decrease
pressure until the correct LOW value is met.
8. See the specification plate on rear of broiler for pressure settings.
9. Turn unit off.
10. Replace regulator cover screw.
11. Reconnect quick disconnect to the valve's "HI" pin.
12. Remove regulator cover screw from the HIGH outlet pressure regulator adjust tower.
13. Turn unit on.
14. Read pressure value and turn regulator screw clockwise to increase pressure and counter clockwise to decrease
pressure until the correct HIGH value is met.
15. Turn unit off.
16. Disconnect hose from valve pressure boss.
17. Use Allen key to turn the outlet pressure test screw clockwise to stop the flow of gas.
PN: 1000-605 | User Manual – Prince Castle Flame King Broiler
Rev: A
Updated: 4/13/2022
FLAME KING BROILER
B. INSTALLATION
15