Samsung AM080FX A Series Service Manual page 61

System air conditioner outdoor unit
Table of Contents

Advertisement

Product Specifications
2-5 Product Specification (cont.)
2-5-1 Outdoor Unit (cont.)
Image
Model Name
Power Supply
Mode
HP
Performance
Capacity (Nominal)
Power Input (Nominal)
Current Input (Nominal)
Power
Running Current
Power Consumption
MCA(Minimum Circuit Amps)
MFA/MOP(Maximum Fuse Amps)
Nominal Cooling 1)
COP
Nominal Heating 2)
ESEER
Type
Output
Compressor
Model Name
Oil
Type
Output x n
Fan
Air Flow Rate
External Static Pressure
Liquid Pipe
Gas Pipe
Piping
High pressure gas pipe
Connection
ODU-IDU
Piping length
After branch
Total piping length
System
ODU-IDU
Level difference
IDU-IDU
Type
Refrigerant
Factory Charging
Sound Pressure
Sound
Sound Power
Net Weight
External
Shipping Weight
Dimension
Net Dimension (WxHxD)
Shipping Dimension (WxHxD)
Operating
Cooling
Heating
Temp. Range
Safety device
Item
1) Nominal cooling capacities are based on;
- Indoor temperature : 27°C DB, 19°C WB
- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
2) Nominal heating capacities are based on;
- Indoor temperature : 20°C DB, 15°C WB
- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
3) Allowed combination ratio of the total rated indoor unit capacity over the rated outdoor unit capacity is 50~130%.
4) Sound power level is an absolute value that a sound source generates.
Sound pressure level is a relative value, depending on the distance and acoustic environment.
Sound values are obtained in an anechoic room.
Sound values of multi combination are theoretical values based on sound results of individual installed units.
5) These products contain R410A which is fluorinated greenhouse gas.
6) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.
(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit. When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information.
※ In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
Samsung Electronics
Φ, V, Hz
-
HP
kW
Cooling
Btu/h
kW
Heating
Btu/h
Cooling 1)
kW
Heating 2)
Cooling 1)
A
Heating 2)
Cooling
A
Heating
Max
Cooling
kW
Heating
A
A
W/W
-
kW
-
Type
-
Initial Charge
cc
-
W
m³/min
l/s
mmAq
Max.
Pa
Type
Φ, mm
Φ, inch
Type
Φ, mm
Φ, inch
Φ, mm
Φ, inch
Max.
m
Max.
m
Actual
m
Outdoor unit in highest position
m
Indoor unit in highest position
m
Max.
m
-
kg
Cooling
dB(A)
Heating
kg
kg
mm
mm
1
-
2
-
3
-
4
-
Product Specifications
AM140KXVAGH/TK
AM160KXVAGH/TK
3/AC380-415/50
3/AC380-415/50
HEAT PUMP
HEAT PUMP
14
16
40.0
45.0
136,500
153,500
45
50.4
153,500
172,000
10.93
12.10
10.16
11.61
17.50
19.40
16.30
18.60
17.50
19.40
16.30
18.60
25.00
32.00
10.93
12.10
10.16
11.61
25.00
32.00
32.00
40.00
3.660
3.720
4.430
4.340
-
-
INV x 1EA
INV x 1EA
6.39 x 1
7.81 x 1
DS-GB066FA*
DS4G*5080F*
PVE
PVE
1100
1400
Propeller + BLDC
Propeller + BLDC
620 x 2
620 x 2
255
255
4250
4250
8
8
78.45
78.45
Braze connection
Braze connection
12.7
12.7
1/2"
1/2"
Braze connection
Braze connection
28.58
28.58
1+1/8"
1+1/8"
-
-
-
-
200(220)
200(220)
90
90
1000
1000
110
110
110
110
50
50
R410A
R410A
7.7
8.4
61
63
63
65
81
83
226
253
246
273
1295x1695x765
1295x1695x765
1363x1887x832
1363x1887x832
-5 ~ 48
-5 ~ 48
-25 ~ 24
-25 ~ 24
70
Samsung Electronics
AM180KXVAGH/TK
AM200KXVAGH/TK
3/AC380-415/50
3/AC380-415/50
HEAT PUMP
HEAT PUMP
18
20
50.4
56.0
172,000
191,100
56.7
63
193,500
215,000
12.60
14.18
11.91
13.91
20.20
22.70
19.10
22.30
20.20
22.70
19.10
22.30
39.20
42.00
12.60
14.18
11.91
13.91
39.20
42.00
50.00
63.00
4.000
3.950
4.760
4.530
-
-
INV x 1EA
INV x 2EA
7.81 x 1
5.18 x 2
DS4G*5080F*
DS-GB052FA*
PVE
PVE
1400
1100 x 2
Propeller + BLDC
Propeller + BLDC
620 x 2
620 x 2
290
290
4833
4833
8
8
78.45
78.45
Braze connection
Braze connection
15.88
15.88
5/8"
5/8"
Braze connection
Braze connection
28.58
28.58
1+1/8"
1+1/8"
-
-
-
-
200(220)
200(220)
90
90
1000
1000
110
110
110
110
50
50
R410A
R410A
8.4
8.4
64
65
66
67
84
87
255
277
275
297
1295x1695x765
1295x1695x765
1363x1887x832
1363x1887x832
-5 ~ 48
-5 ~ 48
-25 ~ 24
-25 ~ 24
High pressure switch
Fan driver overload protector
Inverter overload protector
PC board fuse
AM220KXVAGH/TK
3/AC380-415/50
HEAT PUMP
22
61.6
210,200
69.3
236,500
17.35
16.70
27.80
26.80
27.80
26.80
44.60
17.35
16.70
44.60
63.00
3.550
4.150
-
INV x 2EA
6.39 x 2
DS-GB066FA*
PVE
1100 x 2
Propeller + BLDC
620 x 2
290
4833
8
78.45
Braze connection
15.88
5/8"
Braze connection
28.58
1+1/8"
-
-
200(220)
90
1000
110
110
50
R410A
8.4
65
67
89
285
305
1295x1695x765
1363x1887x832
-5 ~ 48
-25 ~ 24
71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents