Samsung AM080FX A Series Service Manual page 43

System air conditioner outdoor unit
Table of Contents

Advertisement

Product Specifications
2-5 Product Specification (cont.)
2-5-1 Outdoor Unit (cont.)
Power Supply
Mode
Performance
Capacity
(Nominal)
Power Input
(Nominal)
Current Input
(Nominal)
Power
Running Current
Power Consumption
MCA(Minimum Circuit Amps)
MFA/MOP(Maximum Fuse Amps)
COP
Compressor
Oil
Fan
External Static
Pressure
Piping
Connection
Piping length
Total piping length
Level difference
Refrigerant
Sound Pressure
Sound
Net Weight
External
Shipping Weight
Dimension
Net Dimension (WxHxD)
Shipping Dimension (WxHxD)
Operating
Cooling
Temp. Range
1) Nominal cooling capacities are based on;
- Indoor temperature : 27°C DB, 19°C WB
- Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
2) Nominal heating capacities are based on;
- Indoor temperature : 20°C DB, 15°C WB
- Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
3) Allowed combination ratio of the total rated indoor unit capacity over the rated outdoor unit capacity is 50~130%.
4) Sound power level is an absolute value that a sound source generates.
Sound pressure level is a relative value, depending on the distance and acoustic environment.
Sound values are obtained in an anechoic room.
Sound values of multi combination are theoretical values based on sound results of individual installed units.
5) These products contain R410A which is fluorinated greenhouse gas.
6) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.
(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit. When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information.
※ In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
Samsung Electronics
Image
Model Name
HP
Cooling
Heating
Cooling 1)
Heating 2)
Cooling 1)
Heating 2)
Cooling
Heating
Max
Cooling 1)
Heating 2)
Nominal Cooling 1)
Nominal Heating 2)
ESEER
Type
Output
Model Name
Type
Initial Charge
Type
Output x n
Air Flow Rate
Max.
Liquid Pipe
Gas Pipe
Discharge Gas Pipe
ODU-IDU
Max.
After branch
Max.
System
Actual
Outdoor unit in high-
est position
ODU-IDU
Indoor unit in highest
position
IDU-IDU
Max.
Type
Factory Charging
Cooling
Heating
Sound Power
DVMS HP
DVMS HR
DVMS HP
DVMS HR
DVMS HP
DVMS HR
Heating
AM240HXVAGH
Φ, V, Hz
3/AC380~415/50
-
HEAT PUMP
HP
24
kW
67.2
Btu/h
57,800
kW
75.6
Btu/h
65,000
17.10
kW
19.80
26.83
A
31.06
26.83
A
31.06
55.00
26.83
kW
31.06
60.50
A
75.00
3.930
W/W
3.818
-
-
INV x 2EA
kW
-
-
DS-GB066FA*
-
FVC68D
cc
6200
-
Propeller + BLDC
W
620 x 2
m³/min
310
l/s
5167
mmAq
-
Pa
-
Type
Braze connection
Φ, mm
15.88
Φ, inch
5/8"
Type
Braze connection
Φ, mm
34.92
Φ, inch
1+3/8"
Φ, mm
-
Φ, inch
-
m
200(220)
m
90
m
1000
m
110
m
110
m
50
-
R410A
kg
14.3
-
dB(A)
-
-
360
kg
370
1,295 x 1,695 x 765
kg
1,363 x 1,887 x 832
mm
-5.0 ~ 48.0
mm
-20.0 ~ 24.0
-5.0 ~ 48.0
-15.0 ~ 48.0
-25.0 ~ 24.0
AM260HXVAGH
3/AC380~415/50
HEAT PUMP
26
72.8
62600
81.9
70,400
19.30
21.80
30.28
34.20
30.28
34.20
58.00
30.28
34.20
63.80
75.00
3.772
3.757
-
INV x 2EA
-
DS-GB070FA*
FVC68D
6200
Propeller + BLDC
620 x 2
310
5167
-
-
Braze connection
19.05
3/4"
Braze connection
34.92
1+3/8"
-
-
200(220)
90
1000
110
110
50
R410A
14.3
-
-
-
360
370
1,295 x 1,695 x 765
1,363 x 1,887 x 832
-5.0 ~ 48.0
-20.0 ~ 24.0
-5.0 ~ 48.0
-15.0 ~ 48.0
-25.0 ~ 24.0
42