Product Specifications
2-1 Feature of Product (cont.)
2-1-2 Changes in comparison to basic model (cont.)
 AM240/260/280/300SSS
Changed part
Changed item and feature
Change Main PBA
Main PBA
- Increase MICOM capability
Applies 600V IPM by LC
FAN PBA
resonance buck-converter
- Increases current due to
Inverter PBA
high capacity compressor
(Compressor
- Increases capacitor's capacity
Control
- Applies EMI coil on board
PBA)
(Deletes core in wire)
- Develops 50A EMI PBA
  → Increases coil size and
EMI PBA
fuse capacity
- Improves EMI characteristic.
- Increases current due to
high capacity compressor
REACTOR
- Improved wire connection terminal
- Increases heat cooling capacity
Refrigerant
- Increases pipe size and heat
cooling
exchange area
Samsung Electronics
AM080/100/120/140/160/180
/200/220SSS
AM240/260/280/300SSS
7