Samsung AM080FX A Series Service Manual page 375

System air conditioner outdoor unit
Table of Contents

Advertisement

Key Options
8-4 How to check the view mode using a tact switch (cont.)
AM080~260SXVSSS
Optional item
Input unit SEG1 SEG2 SEG3 SEG4
Emergency operation
for compressor
Individual
malfunction
Capacity correction
Main
for cooling
Capcity correction
Main
for heating
Current
Individual
restriction rate
Oil collection interval
Main
Temperature to
trigger defrost
Main
operation
Fan speed correction
Individual
for outdoor unit
Silent mode for
Main
night-time
Long-piping condi-
tion setting (Setting is
unnecessary if
Main
high-head condition
is set)
Energy saving setting
Main
Samsung Electronics
0
0
0
0
0
1
Set compressor 1 as malfunction state
0
2
Set compressor 2 as malfunction state
0
0
0
1
0
2
0
1
0
3
0
4
0
5
0
6
0
0
0
1
0
2
0
3
0
2
0
4
0
5
0
6
0
7
0
8
0
0
0
1
0
2
0
3
0
4
0
5
0
3
0
6
0
7
0
8
0
9
1
0
1
1
0
0
0
4
0
1
0
0
Apply setting when the product is
0
5
0
1
being installed in humid area such as
0
6
0
0
0
0
0
1
0
2
0
7
0
3
0
4
0
5
0
6
0
0
0
1
0
9
0
2
0
0
1
0
0
1
Function of the option
Disabled (Factory default)
7-9 (Factory default)
5-7
9-11
10-12
11-13
12-14
13-15
3.0 (Factory default)
2.5
2.6
2.7
2.8
2.9
3.1
3.2
3.3
100% (Factory default)
0.95
0.9
0.85
0.8
0.75
0.7
0.65
0.6
0.55
0.5
No restriction
Factory default
Shorten the interval by 1/2
Factory default
near river or lake
Factory default
Disabled (Factory default)
LEVEL 1/Auto
LEVEL 2/Auto
LEVEL 3/Auto
LEVEL 1/External contact
LEVEL 2/External contact
LEVEL 3/External contact
Disabled (Factory default)
LEVEL 1
LEVEL 2
Disabled (Factory default)
Enabled
Remarks
E560 will occur when all the
compressors are set as
malfunction state.
Targeted evaporation temperature
[?C] (When low temperature value is
set, discharged air temperature of the
indoor unit will decrease)
Targeted high pressure [MPa] (When
low pressure value is set, discharged
air temperature of the indoor unit will
decrease)
When restriction option is set,
cooling and heating
performance may decrease
Enable the silent mode for
night-time
(Itoperates automatically
depending on the temperrature.)
However, if the external contact
ineterface module(MIM-B14) is used,
entering the silent mode is available
with contact signal
When equivalent length of farthest
indoor unit from the outdoor unit is
between 100~170m
When equivalent length of farthest
indoor unit from the outdoor unit is
over 170m
Energy saving mode triggers when
the room temperature reaches desired
temperature while
operating in heating mode.
394

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents