Samsung AM080FX A Series Service Manual page 24

System air conditioner outdoor unit
Table of Contents

Advertisement

Product Specifications
2-2 Model names of Indoor/Outdoor Unit (cont.)
2-2-1 Outdoor unit combination (cont.)
■ DVM S Premium energy efficiency type (Heat recovery)
System Model
Capa
Code
8HP
AM080JXVHGR/EU
10HP
AM100JXVHGR/EU
12HP
AM120JXVHGR/EU
14HP
AM140JXVHGR/ET
16HP
AM160JXVHGR/ET
18HP
AM180JXVHGR/ET
20HP
AM200JXVHGR/ET
22HP AM220MXVGNR2ET
24HP AM240MXVGNR2ET
26HP AM260MXVGNR2ET
28HP AM280MXVGNR2ET
30HP AM300MXVGNR2ET
32HP AM320MXVGNR2ET
34HP AM340MXVGNR2ET
36HP AM360MXVGNR2ET
38HP AM380MXVGNR2ET
40HP AM400MXVGNR2ET
42HP AM420MXVGNR2ET
44HP AM440MXVGNR2ET
46HP AM460MXVGNR2ET
48HP AM480MXVGNR2ET
50HP AM500MXVGNR2ET
52HP AM520MXVGNR2ET
54HP AM540MXVGNR2ET
56HP AM560MXVGNR2ET
58HP AM580MXVGNR2ET
60HP AM600MXVGNR2ET
62HP AM620MXVGNR2ET
64HP AM640MXVGNR2ET
66HP AM660MXVGNR2ET
68HP AM680MXVGNR2ET
70HP AM700MXVGNR2ET
72HP AM720MXVGNR2ET
74HP AM740MXVGNR2ET
76HP AM760MXVGNR2ET
78HP AM780MXVGNR2ET
80HP AM800MXVGNR2ET
82HP AM820MXVGNR2ET
84HP AM840MXVGNR2ET
86HP AM860MXVGNR2ET
88HP AM880MXVGNR2ET
90HP AM900MXVGNR2ET
▶ Make sure to use an indoor unit that is compatible with DVM S.
▶ Indoor units can be connected within the range indicated in following table.
▶ If the total capacity of the connected indoor units exceeds the indicated maximum capacity, cooling and heating capacity of the indoor unit may
decrease.
▶ Total capacity of the connected indoor units can be allowed from 50% to 130% of the total outdoor unit capacity.
0.5 × Σ( Outdoor unit capacity) ≤ Total capacity of the connected indoor units ≤ 1.3 × Σ( Outdoor unit capacity)
※ You can connect maximum 64 indoor units to the outdoor unit. Maximum quantity of connectable indoor unit is set to 64 since outdoor unit only
support up to 64 communication address. Indoor unit address can be assigned from 0~63. If the indoor unit address was assigned from 64~79, E201
error will occur.
※ Maximum 32 Wall-mount type indoor units with EEV (AMSSSFNQDEHS, AMSSSJNVDKHS) can be connected.
▶ In case of combining modules more than 90HP, please consult the manufacturer when connecting the indoor unit and deciding on piping length in
accordance with design of the building.
Samsung Electronics
No. of Modules
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP
1
1
1
1
1
1
1
1
1
2
1
2
2
1
2
1
2
2
3
2
2
2
3
1
3
1
3
1
3
1
3
1
3
3
1
3
1
3
3
1
3
4
1
4
1
4
4
4
1
4
4
4
4
4
4
4
4
4
4
Capacity of Single Unit (HP)
1
1
1
1
1
2
1
1
1
1
1
1
2
1
1
1
1
2
1
1
2
1
1
1
2
3
2
1
3
1
3
2
4
3
2
1
3
2
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
2
3
1
1
1
2
1
1
1
1
1
1
1
1
2
19