Welbilt MERRYCHEF conneX Service & Repair Manual page 62

Microwave combination oven
Hide thumbs Also See for MERRYCHEF conneX:
Table of Contents

Advertisement

5 Service information
1.
Ensure the cavity is close to ambient temperature.
2.
Enter the Service Settings / Tests and select 'Recommission Test' from the appliance tests.
After a test has successfully passed, when requested select the green check mark to continue. Selecting the red check mark
as a result of a failure will terminate the recommission test sequence.
Note: If the door is opened during the microwave circuit test, the process will stop and record a failure.
3.
When all the tests have been successfully performed the display shows the recommission test has passed. Select the
green check mark to confirm.
4.
In the event of a recommission test failure, the detail will be recorded in the Error Log. Rectify any error and repeat
the recommission test.
Merrychef conneX
®
service and repair manual
The test will check the appliance in the following order;
Door switch operation
Filter switch operation
Microwave circuits
Cooling fan operation
Convection fan operation
Heater circuit
The test will stop at any point a failure is detected.
Back to contents >
62

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

32z9170

Table of Contents