6 Replacing components
Cavity temperature sensor (thermocouple)
Cavity Overheat Thermostat
The thermostat probe is located on the left-hand side of the cavity. The probe has a self-locating pressing within the bulb,
slotting into the locating bracket held on to the cavity with a single M3 flange nut torqued to 1.2Nm. Ensure when fitting that
the probe is equal length on both sides within the fixing bracket.
The cavity overheat thermostat switch is located at the rear of the oven, mounted on the left-hand side of the magnetron air
flow ductwork, fitted by two M3 x 4 CSK Philips SS Screws and flat washers torqued to 1Nm.
Merrychef conneX
®
service and repair manual
Cavity temperature measuring is done by a
temperature sensor (thermocouple)
connected to the IO Board.
The thermocouple is fitted in the rear of the
cavity from the right-hand side, sealed with
a gasket and held in place by a M7 hex nut.
The manual reset button is now
directly accessible from the rear
of the oven.
Back to contents >
97