6 Replacing components
Mains Cable Entry
The mains cable enters the oven through a PG21 / PG16 cable gland on the
base plate angled bracket at the rear righthand side of the oven.
Catalytic Converters
The upper catalyst is fitted using two M7 hex flange nuts,
tightened to 2.1 Nm.
The lower catalyst, is again fitted using two M7 hex flange nuts,
tightened to 2.1 Nm.
Air Filter Microswitch
The air filter microswitch is located on the bottom front left-hand side of the cavity frame by a M5.5 hex nut and wired
directly to the IO Board (X511).
Merrychef conneX
®
service and repair manual
See section 6.13 for convection fan motor assembly removal to access the catalytic
converters.
Once the fan motor assembly has been removed from the rear of the cavity, the
four M7 hex nuts should be removed at the rear of the cavity (inside) to allow
removal of the internal box and catalytic converters.