Problem
The water inlet
leakage
The water won't
stop/flow out
Dial or button
problems
Short battery life
Possible Cause
1. No filter or not be
placed horizontally
2. The faucet is not the
standard 3/4"
1. Long-term storage and
transportation make the
valve inactive
2. Valve blockage
1. The dial/valve is stuck
2. Accidentally holding the
OK button while inserts
the batteries
1. Mixed use of old and
new batteries
2. Used the carbon
batteries or rechargeable
batteries
Possible Solution
1. Add filter and make sure
it' s placed horizontally in
the inlet.
2. Make sure the faucet is
a 3/4" faucet.
3. Strengthen it with raw
rubber wrap.
Step1. Keep the tap turned
off and turn the timer dial to
ON;
Step2. Select the zone you
want to fix (ZONE1 or
ZONE2) and run manual
watering for 3-5s and stop it ;
Step3. Repeat the Step 2 for
5 to 7 times;
Step4. Try using it normally.
1.Same procedure as above.
2.Turn the dial to the OFF to
check if the valve can be
closed.
1. Use brand new alkaline
batteries.
2. Rechargeable batteries
and carbon batteries
have a short and unstable
battery life, please use the
alkaline batteries instead
of them.

Advertisement