Appendix A The Error Codes
0301h – 03FFh: Floppy Disk Error Codes
Code
0307h
Drive parameter activity failed in
sequential test.
0308h
DMA Overrun error in sequential test.
0309h
Attempt to DMA at 64 KB boundary in
sequential test.
030Ah
Bad sector flag detected.
0310h
CRC or ECC data error in sequential test.
0311h
ECC-corrected data error.
0321h
Change line not working.
0322h
Floppy Speed Error Drive.
0340h
Seek operation failed in sequential test.
0341h
Undefined or invalid command in random
test.
58
Explanation
English
Details/Parts to Check
Floppy disk drive or floppy disk controller error.
Check your floppy disk drive is installed correctly.
Install new floppy disk drive.
If error persists, install new system board.
Diagnostic test error.
Re-run the diagnostic tests.
Diagnostic test error.
Re-run the diagnostic tests.
Diagnostic test error.
Re-run the diagnostic tests.
Diagnostic test error.
Re-run the diagnostic tests.
Diskette error.
Replace diskette.
Floppy disk drive error.
Check your floppy disk drive is installed correctly.
If error persists, install new floppy disk drive.
Floppy disk drive error.
Check your floppy disk drive is installed correctly.
If error persists, install new floppy disk drive.
Floppy disk drive or floppy disk controller error.
Check your floppy disk drive is installed correctly.
Install new floppy disk drive.
If error persists, install new system board.
Floppy disk drive or floppy disk controller error.
Check your floppy disk drive is installed correctly.
Install new floppy disk drive.
If error persists install new system board.