HP ProCurve J8766A Release Note page 59

For the procurve series 4200vl switches
Hide thumbs Also See for ProCurve J8766A:
Table of Contents

Advertisement

included: Enables manager-level SNMP read/write access to the switch's authentica-
tion configuration (hpSwitchAuth) MIB.
excluded: Disables manager-level SNMP read/write access to the switch's authentica-
tion configuration (hpSwitchAuth) MIB.
(Default: included)
Syntax: show snmp-server
The output for this command has been enhanced to display the current access status
of the switch's authentication configuration MIB in the Excluded MIBs field.
For example, to disable SNMP access to the switch's authentication MIB and then display the result
in the Excluded MIB field, you would execute the following two commands.
ProCurve(config)# snmp-server mib hpswitchauthmib excluded
ProCurve(config)# show snmp-server
SNMP Communities
Community Name
---------------- -------- ------------
public
Trap Receivers
Link-Change Traps Enabled on Ports [All] : All
Send Authentication Traps [No] : No
Address
---------------------- ---------------- -------------------
Excluded MIBs
hpSwitchAuthenticationMIB
Figure 24. Disabling SNMP Access to the Authentication MIB and Displaying the Result
An alternate method of determining the current Authentication MIB access state is to use the show
run command.
MIB View Write Access
Manager
Unrestricted
Community
Indicates that SNMP security MIB access is
disabled, which is the nondefault setting.
Release L.10.20 Enhancements
This command disables
SNMP security MIB access.
Events Sent in Trap
Enhancements