CSE-800 Configurator
For the primary interface: "192.168.0.23" . For the secondary interface: "192.168.1.23". Both with subnet
mask "255.255.255.0".
2.
Click in the input field of the IP address and fill out the 4 octets.
Note: An address contains 4 octets with a maximum value of 255.
This must NOT be 0.0.0.0 for static IP-Address assignment
3.
Click in the Subnet mask input fields and fill out the 4 octets as appropriate for the local subnet.
4.
Click in the Default Gateway input fields and fill out the 4 octets. Set the Default-Gateway to the IP-
Address of the router (MUST be on the local subnet!).
Note: This must NOT be 0.0.0.0.
If there is no router on the local subnet then just set this field to any IP-Address on the subnet.
5.
Click in the DNS Servers input field and fill out the preferred DNS servers (maximum 5) in a comma
separated list.
6.
Click Save changes to apply the settings.
Do not use IP address 192.168.2.x for a Subnet mask 255.255.255.0 and IP address 192.168.x.x
for a Subnet mask 255.255.0.0
Use a proxy server
This setting is important for the auto-update feature of the Base Unit, which require internet access.
1.
Check the check box next to Use a proxy server.
Image 6–27 Proxy settings
The proxy settings become available.
2.
Enter the proxy server address. Enter the IP address or hostname.
Some proxy servers need a port number, user name and password, for others is this optional.
3.
Optionally, enter the used server port.
4.
Optionally, enter the user name.
5.
Optionally, enter the password.
6.
Click Save changes to apply the settings.
For the moment, only the primary network connector can be used for API, Management Suite and