Barco VisuPlus R9830602 Instruction Manual
Barco VisuPlus R9830602 Instruction Manual

Barco VisuPlus R9830602 Instruction Manual

Video insertion unit

Advertisement

Quick Links

R5976214
user's manual
P
LUS
Video Insertion Unit
Download from Www.Somanuals.com. All Manuals Search And Download.

Advertisement

Table of Contents
loading

Summary of Contents for Barco VisuPlus R9830602

  • Page 1 R5976214 user’s manual Video Insertion Unit Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 2 R5976214, Current Version Title: – User’s Manual ID-no.: R5976214 Release: June 2003 main issue update chapter 1 chapter 2 chapter 3 chapter 4 chapter 5 corr. chapter 6 chapter 7 chapter 8 chapter 9 new: The corresponding chapters are new or completely revised. corr.: Passages of the corresponding chapter were corrected;...
  • Page 3 30 days after the transfer of risks. In the event of justified notice of complaint, BARCO can repair the fault or provide a replacement at its own discretion within an appropriate period. If this measure proves to be impossible or unsuccessful, the purchaser can demand a reduction in the purchase price or cancellation of the contract (redhibi- tion).
  • Page 4 Revision sheet Barco Control Rooms GmbH An der Rossweid 5, D-76229 Karlsruhe Phone: +49-721-6201-0, Fax: +49-721-6201-298 docu.de.bcd@barco.com http://www.barcocontrolrooms.com E-mail: , Web: From: Date: Please correct the following points in this documentation ( R5976214 page wrong correct R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com.
  • Page 5: Table Of Contents

    Contents 1 Introduction ..........................1-1 1.1 How this manual is organized ..................... 1-2 1.2 Styles and Symbols ......................1-3 1.3 Safety Instructions....................... 1-4 1.3.1 Precautions........................1-4 1.3.2 Unpacking of Devices ....................1-6 1.3.3 Installation ........................1-6 1.3.4 Servicing ........................1-6 1.3.5 Cleaning........................
  • Page 6 6.1 Introduction ......................... 6-2 6.2 Notation Conventions......................6-2 6.3 V Internals......................... 6-3 6.4 V Operation Protocol ....................6-4 6.4.1 Error / Info messages ....................6-4 6.4.2 Return value........................ 6-4 6.4.3 ACK / NACK ......................6-4 6.5 Commands........................... 6-5 6.5.1 <CR> .......................... 6-6 6.5.2 SET_BAUDRATE .....................
  • Page 7: Introduction

    1 Intro duction This chapter explains the structure of the manual itself and the used typographic styles and sym- bols. Safety information is provided concerning the operation of computer systems from BARCO. R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 8: How This Manual Is Organized

    Introduction explains the structure of the manual itself and the used typographic styles and symbols. Safety information is provided concerning the operation of computer systems from BARCO. Summary gives an overview about the features of V...
  • Page 9: Styles And Symbols

    1.2 Styles and Symbols The typographic styles and the symbols used in this document have the following meaning: Labels, menus and buttons are printed in the Helvetica bold font. Helvetica bold Condensed Links to both other chapters of this manual and to sites in the Internet are printed condensed.
  • Page 10: Safety Instructions

    1.3 Safety Instructions This section describes safety precautions, which must be observed when installing and operating a product from BARCO. 1.3.1 Precaut ions For your own protection, observe the following safety precautions when installing, operating and servicing your device: Before operating the units please read this manual thoroughly and retain it for future reference!
  • Page 11 Mains lead (AC Power cord) with CEE 7 plug: The wires of the mains lead are colored in accordance with the following code: yellow + green Earth (Ground) blue Neutral brown Line (Life) Figure 1-1 CEE 7 plug Power cord with ANSI 73.11 plug: The wires of the power cord are colored in accordance with the following code.
  • Page 12: Unpacking Of Devices

    1.3.4 Servicin g Mechanical or electrical modifications others than described in this manual must not be made to the devices. BARCO is not liable for damages resulting from modified devices. Only authorized personnel should carry out other maintenance work not explicitly...
  • Page 13: Summary

    2 Summ ary This chapter gives an overview about the features of V R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 14: Properties

    2.1 Proper ties With V (Video Insertion Unit) live video and RGB data can be displayed on A TLAS Display Walls and be integrated into the X window applications or a Microsoft Win- dows desktop controlled by E The video- and RGB-windows displayed by V can be manipulated in contrast, brightness, color etc.
  • Page 15 – Standalone Setup standalone system is mainly used in application areas where there is a need for dis- playing different information sources (Video or RGB) within a matrix of display systems (projec- tors or other display medium). Sources displayed may be moved, re-scaled and treated in a number of other ways via control software, which is installed on a control PC.
  • Page 16 Control Room Management Software O and A SIRIS POLLO Depending on the used operating system of the E and control PC respectively, either the wall management software O or A can be used to control the V SIRIS POLLO is used for a V with digital or analog output in a V –...
  • Page 17: Getting Started

    3 Getti ng Started This chapter describes the set up of V If your V is already configured within your working place you can skip this chapter and 4 Operating continue with section R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com.
  • Page 18: Examining

    3.1 Examin ing 3.1.1 V The front of V looks like this or similar: air supply handle of filter mounting restart button LED: status LED: power on LCD display for system messages reserved for future use! reserved for future use! power button Figure 3-1 front view of V...
  • Page 19 The Back The back of your V looks like this or similar: 10, 19 air supply output card 0 output card 1 output card 2 output card 3 input card 0 input card 1 input card 2 input card 3 mains connection processor board Figure 3-2...
  • Page 20: Control Pc For Visup

    3.1.2 Control PC for V Standalone The control PC for V standalone comes with its own documentation to you, please read it carefully. The control PC provides a serial and a parallel port that is used to connect to the processor board of the V and therewith control the V .
  • Page 21: Cabling

    3.2 Cabling 3.2.1 Power S upply Check the power rating on your outlet before connecting V to the wall outlet or to a power strip. Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building. is designed to operate with single-phase power systems having a grounded neutral conductor.
  • Page 22: Digital Output Unit (Dvi)

    3.2.2 Digital O utput Unit (DVI) There are three different types of output units for connecting to the projection modules of an or A Display Wall: digital output unit DVI, digital output unit MDR26 and ana- TLAS log output unit. To connect to digital projection modules the digital output unit DVI can be used.
  • Page 23 Order The (digital or analog) output units are numbered from top to bottom beginning with OPU 0 VISU+ OPU DVI OPU 1 VISU+ OPU DVI OPU 2 VISU+ OPU DVI OPU 3 VISU+ OPU DVI Figure 3-6 numbering of output units If multiple V are used, the output units are numbered continuously beginning with the out- put units of the V...
  • Page 24: Digital Output Unit Mdr26

    3.2.3 Digital O utput Unit MDR26 can be equipped with digital output units with MDR26 connector for connecting digital projection modules of an O or A Display Wall. TLAS Plus Within a Visu – Eos configuration the graphical information of Eos is also Plus inserted into the output unit of Visu Each of these output units provides the facility for connecting one projection module.
  • Page 25: Analog Output Unit

    3.2.4 Analog Output Unit can be equipped with analog output units for connecting analog projection modules or CRT monitors. Plus Within a Visu – Eos configuration the graphical information of Eos is as well inserted in the OPU. Each of these output units provides the facility for connecting one analog projection module or CRT monitor.
  • Page 26 D15 – D15 Cable Within a V – E setup the D15 – D15 cable is used to connect the analog output of E with the connector of the analog input unit. RGB in Figure 3-11 D15 – D15 cable D15 –...
  • Page 27: Video Input Unit

    3.2.5 Video In put Unit can be equipped with video input units to insert video data. Each of these video input units provides the facility for connecting one video source and to loop through the signal. Connectors VIDEO in VIDEO out SVHS in SVHS out Figure 3-13...
  • Page 28: Rgb Input Unit

    Use an extra device like RGB/Matrix switcher instead! If an RGB signal is connected from a Barco Magic interface then a BNC T-connector has to be used, which has to be connected as close as possible to the RGB input unit. The Hsync and Vsync line have to be terminated with a 75 Ohm terminator.
  • Page 29: Processor Board

    3.2.7 Process or Board The processor board (CPU) contains several connectors to control, reset and synchronize the Connectors serial connection to E or control PC RS232 in horizontal synchronization input HS in horizontal synchronization loop through to proj. vertical synchronization input VS in vertical synchronization loop through to proj.
  • Page 30 Load Cable (D9 – D9) In order to upload the operating system to the V devices and control the V windows (position and aspect ratio) a serial connection has to be established between the V and E or the control PC. The serial cable is also used to establish the serial connection between multiple V Figure 3-18 load cable...
  • Page 31 BNC - BNC Cable The BNC – BNC cable is used to establish the connection between multiple V in a chain. It connects the connector [7] of a V with the connector [6] RESET out RESET in of the next V Figure 3-20 BNC - BNC cable R5976214...
  • Page 32: Starting Up

    3.3 Startin g Up 3.3.1 Connec ting 3.2.1 Power Plug in the power cable on the back panel of your V . Please refer to section Supply Connect the serial port of the Multiport I/O Card of E and the control PC respectively with the port of the processor board.
  • Page 33 – E setup (digital) If E controls V and data is transferred digitally, connect the data cables as follows: Connect the first graphic port of E with the ports of the first digital output unit of V 3.2.3 Digital Output Unit so on.
  • Page 34 – E setup (analog) If E controls V and analog data is transferred, connect the data cables as follows: Connect the first graphic port of E with the ports of the first analog output unit of V 3.2.4 Analog Output Unit and so on.
  • Page 35 VisuPlus – standalone setup (digital and analog) If V is setup in a standalone configuration and is controlled by a control PC the cabling of the digital or analog output units follows the same scheme. Therefore just the cabling for the ana- log setup is explicitly given.
  • Page 36: Switching On

    3.3.2 Switchi ng on Switch on V by applying the on front! When multiple V are used, power switch [9] the order in which the V are switched on is of no importance. When the system is powered on, the on the front panel will lighten up.
  • Page 37: Operating

    4 Oper ating This chapter shows the capabilities that V offers for displaying video and RGB signals. R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 38: Display Capabilities

    4.1 Display Capabilities Up to four input units can be integrated in V to be able to display video or RGB sources on an A or O Display Wall. RGB and video input units can be integrated within the TLAS same V device.
  • Page 39: Video Input Unit

    4.1.1 Video In put Unit Video data in the video input unit is processed with a color depth of 24 bit. At a video input unit can be connected. Only one source can be composite video SVHS video displayed at one time. The video input unit supports the most common video standards.
  • Page 40: Rgb Input Unit (Sxga)

    4.1.2 RGB Inp ut Unit (SXGA) The RGB input unit has a maximum resolution of 1280×1024 pixels. It processes data internally with a color depth of 16 bpp. 1280×1024 max. resolution 160 MHz max. pixelclock 100 kHz max. line rate 120 Hz max.
  • Page 41: Output Units

    4.1.3 Output Units Module Overlapping Windows If the V is equipped with analog output units and a window is positioned on multiple pro- jection modules, at the vertical border of a module two pixels are not displayed. One can choose whether two pixels on the left or two pixels on the right or one pixel on each side is not displayed.
  • Page 42: Video Switcher

    4.1.4 Video S witcher Integrating a video switcher improves the possibilities of moving video and RGB windows on the Display Wall. A connected video or RGB source can then not only be displayed in the display section of one V but can be moved within the whole area of all V connected to the source via the video switcher.
  • Page 43: Operation

    4.2 Operat ion The V is controlled by means of E or the control PC. Therefore on E and the control PC respectively the Wall Management Software O or A has to be installed, depending on SIRIS POLLO the operating system. The operation of the V is explained in the user’s manual of O SIRIS well as in the user’s manual of A...
  • Page 44: Maintenance

    5 Main tenance requires very little maintenance. Some maintenance operations are nevertheless necessary to maintain distortion free operation of V R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 45: Exchange Of Consumables

    5.1 Exchan ge of Consumables 5.1.1 Replaci ng the Filter Pad of V The filter pad of the V case has to be changed in intervals, depending on the grade of pollu- 7.3 Order Codes tion of the air. See section for ordering filter pads.
  • Page 46: Command Reference

    6 Com mand Reference This chapter provides an overview of the serial commands used to control the V and an in- struction how to use them. Usually E and the control PC take use of these protocols by means of the wall management software.
  • Page 47: Introduction

    RGB input settings (horizontal and vertical resolution, horizontal and vertical phase, ...). Source placement. The following sections describe this last protocol. Please contact Barco for the download protocol. 6.2 Notatio n Conventions The syntax elements of V commands are signified as follows: Angled brackets surrounding a syntax item indicate a user-defined argu- <...
  • Page 48: Isu Lus Internals

    LU S 6.3 V Internals The internal data structure is been split into three different tables: source table, window table and input unit table. These three tables are stored on each V in the chain. The source table and the window table have the same content on each V , as they contain information about the configuration of the whole system.
  • Page 49: Operation Protocol

    LU S 6.4 V Operation Protocol The V -operation protocol is completely ASCII based. Characters are placed in capitals. Numbers are transferred as ASCII coded words (example number -128 is transferred as ASCII(- 128)). Every command (send from host computer or returning from V ) must end with a .
  • Page 50: Commands

    6.5 Comm ands There are two ways of sending commands to a V One way is sending the complete ASCI command name. The other way is sending a command shortcut, which is a ASCII(#) followed by the command in- dex incremented by the ASCII(A). This method improves the speed of communication. It also don’t send info messages to its LCD-display or source of commands (E / control PC).
  • Page 51 6.5.1 <CR> The <CR> command is used to check if the first V answers. The first V sends its prompt VISU> back to the host computer. This is the only command that doesn’t end with ACK or NACK! Syntax: VISU <CR> Return from first V VISU>...
  • Page 52: Verbose

    6.5.4 VERBO SE The VERBOSE command enables or disables the V from sending messages. INFO Syntax: VISU VERBOSE <VALUE> <CR> VISU #Z <VALUE> <CR> Arguments of VERBOSE: Value Description disable the V from sending messages INFO enable the V to send messages INFO Table 6-4...
  • Page 53 vertical resolution 1..1024 horizontal orbit size ( HorbitSize for V on CRT projectors 1..16 for all other cases vertical orbit size ( VorbitSize for V on CRT projectors 1..16 for all other cases horizontal orbit step Hphase ) .. HorbitSize Only valid when orbiting is used! Hphase vertical orbit step...
  • Page 54 6.5.6 OPU_SE T_POS The OPU_SET_POS command has two functions. One of them is reinitializing the V . The other one is used to give a specific output unit an X and Y coordinate. These coordinates are the physical position of the outputs on the matrix of the Display Wall. Syntax for Reinitializing: VISU OPU_SET_POS –1 -1 –1 <CR>...
  • Page 55: Opu_Set_Param / Opu_Get_Param

    6.5.7 OPU_SE T_PARAM / OPU_GET_PARAM The OPU_SET_PARAM command is used to configure output unit specific settings. The OPU_GET_PARAM command is used to retrieve those settings. Syntax: VISU OPU_SET_PARAM <OpuNr> <Parameter> <Value> <CR> VISU #Q <OpuNr> <Parameter> <Value> <CR> VISU OPU_GET_PARAM < OpuNr> < Parameter> <CR> VISU #R <...
  • Page 56: Win_Set_Pos

    Values of <WinNr>: Value Description create link to this window 0..63 remove the link, not used IpuNr Table 6-8 values of <WinNr> of IPU_LNK_TO_WIN command Example: : input unit 0 linked to window 0 VISU IPU_LNK_TO_WIN 0 0 <CR> VISU IPU_LNK_TO_WIN 1 –1 <CR> : input unit 1 not used VISU IPU_LNK_TO_WIN 2 1 <CR>...
  • Page 57: Win_Set_Viewport

    6.5.11 WIN_SE T_VIEWPORT The WIN_SET_VIEWPORT specifies the displayed portion of a source in its window. The view- port values are given in pro mile! Syntax: VISU WIN_SET_VIEWPORT <WinNr> <XStart> <YStart> <XEnd> <YEnd> <CR> VISU #E <WinNr> <XStart> <YStart> <XEnd> <YEnd> <CR> 6.5.12 WIN_BR ING_TO_TOP The WIN_BRING_TO_TOP command brings a -window to the top.
  • Page 58 6.5.14 WIN_SE T_PARAM / WIN_GET_PARAM The WIN_SET_PARAM command is used to configure source independent window settings. The WIN_GET_PARAM command is used to retrieve those settings. Syntax: VISU WIN_SET_PARAM <WinNr> <Parameter> <Value> <CR> VISU #H <WinNr> <Parameter> <Value> <CR> VISU WIN_GET_PARAM <WinNr> <Parameter> <CR> VISU #I <WinNr>...
  • Page 59: Src_Set_Param / Src_Get_Param

    6.5.15 SRC_SE T_PARAM / SRC_GET_PARAM The SRC_SET_PARAM command is used to configure source specific settings. The SRC_GET_PARAM command is used to retrieve those settings. Syntax: VISU SRC_SET_PARAM <SrcNr> <SrcType> <Parameter> <Value> <CR> VISU #N <SrcNr> <SrcType> <Parameter> <Value> <CR> VISU SRC_GET_PARAM <SrcNr> <SrcType> <Parameter> <CR> VISU #O <SrcNr>...
  • Page 60 RGB parameters and correlated values: Parameter Value Description source input type disabled enabled horizontal resolution 0..1280 vertical resolution 0..1024 0..511 horizontal phase vertical phase 0..255 horizontal total pixels 0..2047 sampling phase 0..31 red coarse gain 0..67 red fine gain 0..31 red cut off 0..255 0..67...
  • Page 61: Enable_Update

    6.5.16 ENABL E_UPDATE The ENABLE_UPDATE command enables or disables the updating of the Display Wall. When disabled, values can be loaded to the V , but will not be updated on the Display Wall. When enabled, a forced update will be done and loading new parmeters will every time update the Dis- play Wall.
  • Page 62: Try_Enable_Update

    6.5.17 TRY_EN ABLE_UPDATE The TRY_ENABLE_UPDATE tries an update to see if there is bandwidth enough within the to transfer all source data from inputs to outputs. Syntax: VISU TRY_ENABLE_UPDATE <CR> VISU #Y <CR> If there is bandwidth enough, no error messages will come back; it can be proceeded with a real ENABLE_UPDATE.
  • Page 63: Way Of Operations

    6.6 Way of operations Configuration of V Following describes the order in which the V has to be configured: Check communication with the first V in the chain VISU<CR> Change baudrate if required VISU SET_BAUDRATE <Value> <CR> Configure the chain VISU AUTO_CONFIG 0 <LastVisuNrInChain>...
  • Page 64 Operation of V Following describes the operation of V after configuration: disable updates VISU ENABLE_UPDATE 0 <CR> (re-) define Links between input units → windows → sources VISU IPU_LNK_TO_WIN <IpuNr> <WinNr> <CR> VISU WIN_LNK_TO_SRC <WinNr> <SrcNr> <CR> (re-) define Window position, size, viewport and priority VISU WIN_SET_POS <WinNr>...
  • Page 65: Technical Appendix

    7 Tech nical Appendix This chapter provides tabular overviews about the technical details of V , its components and of their interfaces. R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 66: Technical Data

    7.1 Techni cal Data 177mm/435mm/450mm | 6.97 in./17.13 in./17.72 in. dimensions (h/w/d) 14.6kg | 32.2lbs. (base unit) weight 15,98kg | 35.23lbs. (equipped with 4 input and 4 output units) 90 – 240V, 60 - 50Hz power mains 150W power supply 0 ..
  • Page 67 Digital Output Board (MDR26) upscaling functions source priority digital colorkeying digital insertion in an external signal 800×600×24bpp resolution & colors 1024×768×24bpp 1280×1024×24bpp 67MHz (internal) maximum pixelclock 112MHz(from E and to projector) PanelLink graphical output standard propriety bus connection 0..50°C at max. 80% humidity, non condensing operating conditions 220mm×117mm dimensions...
  • Page 68 RGB Input Board A/D conversion functions downscaling frame rate control 1280×1024×24bpp maximal resolution 160MHz maximum pixelclock 100kHz maximum line frequency 120Hz maximum frame frequency separate sync: Hsync + Vsync supported sync types composite sync: Csync sync-on-green 16-bit (R-G-B: 5-6-5) color depth propriety bus connection 0..50°C at max.
  • Page 69 Processor board serial communication handling functions hardware control bus control separate sync: Hsync + Vsync supported sync types proprierty bus connection 0..50°C at max. 80% humidity, non condensing operating conditions 220mm×234mm dimensions 2 55pin 2mm ZPAQ connector to the Visu propriety bus plugs 2 9pin SubMinD connector, RS232 compatible 6 BNC connector...
  • Page 70: Interfaces

    7.2 Interfac es Seen from outside V Processor Board Figure 7-1 D9 female pin assignment Figure 7-2 D9 male pin assignment Signal Shield Figure 7-3 BNC connector pin assignment R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 71 Digital Output Board DVI Data2– Data1– Data0– Data2+ Data1+ Data0+ Data2 Shield Data1 Shield Data0 Shield DDC Clock +5V Power Clock Shield DDC Data Ground (return for Clock+ +5V, Hsync, and Vsync) Hot Plug Detect Clock- Figure 7-4 DVI in and out connector PanelLink pin assignment Digital Output Board MDR26 PanelLink PanelLink...
  • Page 72 PanelLink PanelLink Tx2+ Tx2– Tx1+ Tx1– Tx0+ Tx0– TxC+ TxC– Figure 7-6 MDR26 out connector PanelLink pin assignment Analog Output Board, RGB in – RGB input unit, RGB out red GND green green GND blue blue GND HSYNC VSYNC sync GND Figure 7-7 RGB male connector pin assignment Analog Output Board, RGB out –...
  • Page 73 Video Input Board, Video in/out Signal Shield Figure 7-9 BNC connector pin assignment S-Video Figure 7-10 4-pole mini-DINconnector pin assignment Reset Cable (D25 – BNC) to pin10 signal to pin 1 to pin 21 shield to pin 16 to pin 13 shield to pin 11 Figure 7-11...
  • Page 74 Load Cable (D9 – D9) – – – – – – – – – Figure 7-12 load cable pin assignment R5976214 VisuPlus Video Insertion Unit June 2003 7-10 Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 75: Order Codes

    7.3 Order C odes Hardware user’s manual V Video Insertion Unit, English R5976214 user’s manual E X Terminal, English RSDOC30612 base unit R9830602 digital output board DVI R9842140 analog output board, to be used in V – E setup R9830621 analog output board, to be used in V stand alone setup R9830623...
  • Page 76 user’s manual O R5976144 SIRIS support license R9832080 Wall Management Software, Basic R9830830 SIRIS (containing: Base module R9832000 remote pointer R9832001 insertion R9832002 projector control module R9832003 control manager) R9832004 Wall Management Software, Full Version R9830835 SIRIS (containing: Basic SIRIS matrix switch control module R9832005 UPS security control module...
  • Page 77: Troubleshooting

    8 Troub leshooting Check this chapter for help, if your V does not operate properly and for information how to contact the technical support of BARCO. R5976214 VisuPlus Video Insertion Unit June 2003 Download from Www.Somanuals.com. All Manuals Search And Download.
  • Page 78: Communication To Visup

    8.1 Comm unication to V Fails The LCD display on the front of V shows system messages concerning operation and errors. The error messages that may appear, are all related with commands sent from an E or control PC. The software on these devices will take care of the generated error messages. In the case that the communication to the V (-chain) fails (e.g.
  • Page 79: Hot Line

    8.2 Hot Lin e Feel free to contact us if you have any further questions! BARCO N.V. Projection Systems - Europe Nordlaan 5, B-8520 Kuurne Phone: +32-56-368-211, Fax: +32-56-368-251 support.bcd@barco.com www.barcocontrolrooms.com E-mail: , Web: R5976214 VisuPlus Video Insertion Unit June 2003...
  • Page 80: Index

    9 Index 9.1 Table o f Tables Table 2-1 interaction of V and X Server ............... 2-4 SIRIS Table 3-1 color coding of BNC connectors..................3-10 Table 4-1 supported video standards ....................4-3 Table 4-2 display properties of RGB input unit ................... 4-4 Plus Table 6-1 syntax elements of Visu commands ................
  • Page 81: Table Of Figures

    9.2 Table o f Figures Figure 1-1 CEE 7 plug Figure 1-2 ANSI 73.11 plug Figure 2-1 V – E setup Figure 2-2 V – standalone setup Figure 3-1 front view of V Figure 3-2 rear view of V Figure 3-3 mains connection of V Figure 3-4 digital output unit (DVI) Figure 3-5 DVI-D to DVI-D cable Figure 3-6 numbering of output units...
  • Page 82 Free Manuals Download Website h p://myh66.com h p://usermanuals.us h p://www.somanuals.com h p://www.4manuals.cc h p://www.manual-lib.com h p://www.404manual.com h p://www.luxmanual.com h p://aubethermostatmanual.com Golf course search by state h p://golfingnear.com Email search by domain h p://emailbydomain.com Auto manuals search h p://auto.somanuals.com TV manuals search h p://tv.somanuals.com...

Table of Contents