RUN Lamp (No.6 Figure 2-1): green, long lighting when charging and flash when discharging;
ALM Lamp (No.7 Figure 2-1 7): red, flashes when alarm and long bright if equipment failure or
protected;
Battery capacity indicator (No.8 Figure 2-1): 6 green lamps, each light represent 16.6%
capacity.
LED Indicators Instructions
Protectio
Battery
n /
Statues
Alarm /
Normal
Shut
Down
Standby
Normal
Normal
Charge
Protecti
on
Normal
Discharg
e
Protecti
on
Note: The flashing instructions, flash 1 - light 0.25s / off 3.75 seconds; flash 2 - 0.5s light / 0.5s off;
flash
3 - 0.5s light / 1.5s off
BMS function:
Protection and Alarm
Charge/Discharge End
Charge Over Voltage
Charge/Discharge Over Current
High/Low Temperature
Short Circuit
Power Cable Reverse
RUN
ALM
●
●
●
Off
Off
Off
Flash1
Off
Off
Light
Off
Off
Light
Off
Flash3
Off
Off
Light
Off
7 / 19
Capacity LED
●
●
●
●
Off
Off
Off
Off
Off
Off
Off
Off
Based on capacity
Off
Off
Off
Off
Based on capacity
Off
Off
Off
Off
Management and Monitor
Cells Balance
Intelligent Charge Model
Charge/Discharge Current Limit
Capacity Retention Calculate
Administrator Monitor
Operation Record
Descriptions
●
Off
All off
Off
Indicates Standby
The highest capacity
indicator LED flashes
(flash 2), others lighting
Stop charging, ALM
Off
lighting
Indicate based on
capacity
Stop discharging, ALM
Off
lighting
16BISV0903